Electronic Components Datasheet Search |
|
S2EB-L2-5V Datasheet(PDF) 4 Page - Nais(Matsushita Electric Works) |
|
S2EB-L2-5V Datasheet(HTML) 4 Page - Nais(Matsushita Electric Works) |
4 / 4 page S 222 ACCESSORIES S Relay Socket, S-PS Specifications (Note: Don't insert or remove relays while in the energized condition.) Breakdown voltage 1,500 Vrms between terminals Insulation resistance More than 100 M Ω between terminals at 500 V DC Mega Heat resistance 150 ±3°C (302 ±5.4°F) for 1 hour. Maximum continuous current 4 A Dimensions PC board pattern (Copper-side view) 12.4 ±0.6 .488 ±.024 18.3 ±0.6 .720 ±.024 15.5 ±0.6 .610 ±.024 3.4 ±0.3 .134 ±.012 0.4 ±0.1 .016 ±.004 1.2 ±0.3 .047 ±.012 4.85 ±0.3 .191 ±.012 5.08 ±0.3 .200 ±.012 32.4 ±0.6 1.276 ±.024 1.5 ±0.3 .059 ±.012 1.5 ±0.3 .059 ±.012 7.62 ±0.3 .300 ±.012 Terminal width: 1.3 .051 Terminal thickness: 1.2 .047 7.6 .299 5.08 .200 5.08 .200 5.08 .200 5.08 .200 5.08 .200 12-1.6 DIA. HOLE 12-.063 DIA. HOLE mm inch Inserting and removing method Inserting method: Insert the relay as shown in Fig. 1 unit the rib of the relay snaps into the clip of the socket. Rib Fig. 1 Removing method: (1) Remove the relay straight from the socket holding the shaded portion of the relay as shown in Fig. 2. Fig. 2 (2) When sockets are mounted in close proximity, use a slotted screw driver as shown in Fig. 3. Fig. 3 NOTES 1. Special use of 2 coil latching types: 2 ways can be considered if 2 coil latching types are used as 1 coil latching types. (A) Reverse polarity is applied to the set coil of 2 coil latching type. (B) By shorting terminals 12 and 7, apply plus to 1, minus to 6 at set and plus to 6, minus to 1 at reset. Applied coil voltage should be the same as the nominal. Oper- ating power will be reduced to one-half. Reset position of 2a2b type 2. Soldering operations should be accom- plished as quick as possible; within 10 seconds at 250 °C 482°F solder tempera- ture or 3 seconds at 350 °C 662°F. The header portion being sealed with epoxy resin, undue subjection to heat may cause loss of seal. Solder should not be permitted to remain on the header. 123456 12 11 10 9 8 7 - + CAUTIONS FOR USE Based on regulations regarding insulation distance, there is a re- striction on same-channel load connections between terminals No. 2, 3 and 4, 5, as well as between No. 8, 9 and 10, 11. See the figure below for an example. 4 2 5 3 10 9 4 8 11 5 23 9 8 11 • Between 2, 3 and 4, 5: • Between 10, 11 and 8, 9: same channels, therefore possible same channels, therefore possible • Between 2, 3 and 4, 5: • Between 10, 11 and 8, 9: different channels, therefore not possible different channels, therefore not possible 10 No good Good For Cautions for Use, see Relay Technical Information (Page 48 to 76). 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog |
Similar Part No. - S2EB-L2-5V |
|
Similar Description - S2EB-L2-5V |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |