Electronic Components Datasheet Search |
|
AD4020 Datasheet(PDF) 6 Page - Analog Devices |
|
AD4020 Datasheet(HTML) 6 Page - Analog Devices |
6 / 37 page Data Sheet AD4020 Rev. A | Page 5 of 36 Parameter Test Conditions/Comments Min Typ Max Unit VIO Only 1.8 MSPS, high-Z mode disabled 1.0 mW Energy per Conversion 8.3 nJ/sample TEMPERATURE RANGE Specified Performance TMIN to TMAX −40 +125 °C 1 The acquisition phase is the time available for the input sampling capacitors to acquire a new input with the ADC running at a throughput rate of 1.8 MSPS. 2 A throughput rate of 1.8 MSPS can only be achieved with turbo mode enabled and a minimum SCK rate of 71 MHz. Refer to Table 4 for the maximum achievable throughput for different modes of operation. 3 Transient response is the time required for the ADC to acquire a full-scale input step to ±2 LSB accuracy. 4 The minimum and maximum values are guaranteed by characterization, but not production tested. 5 See the 1/f noise plot in Figure 18. |
Similar Part No. - AD4020 |
|
Similar Description - AD4020 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |