Electronic Components Datasheet Search |
|
IMA-x400-48-ZNPLI Datasheet(PDF) 4 Page - Delta Electronics, Inc. |
|
IMA-x400-48-ZNPLI Datasheet(HTML) 4 Page - Delta Electronics, Inc. |
4 / 14 page IMA-x400 Power Supply Series Galvanic isolation IMA-x400-xx Input to Output Reinforced 4000 Vac; 2 x MOPP Input to Case Basic 1500 Vac; 1 x MOPP Output to Case Basic 1500 Vac; 1 x MOPP Leakage currents IMA-x400-xx AC Leakage current from Input to earth ground Measured at mains voltage at 60 Hz at 63 Hz Normal condition (low line) 132 Vac < 150 µA < 150 µA Single fault condition (low line) 132 Vac < 250 µA < 260 µA Normal condition (high line) 264 Vac < 300 µA < 300 µA Single fault condition (high line) 264 Vac < 500 µA < 520 µA AC Leakage current from Output to earth ground Measured at mains voltage Typical at 60 Hz 1) Maximum value at 63 Hz 1) Limit per IEC 60601-1 Normal condition 264 Vac 45 µA < 60 µA 100 µA Single fault condition (neutral open) 264 Vac 45 µA < 80 µA 500 µA Single fault condition (ground open) 264 Vac 114 µA < 150 µA 500 µA AC Backdrive fault 264 Vac < 450 µA < 550 µA 5000 µA 1) Meets IEC 60601-1 BF leakage current limit Other features IMA-x400-xx Current Share Bus Pin J3 Pin 11 (CURRENT SHARE_V) Voltage at CS Pin will vary linearly with load current on main output, and will be 6 V at rated load current, when the output voltage is at its rated value. Power Good Pin J3 Pin 9 (PWR_GOOD) Open collector. As soon as AC input voltage and DC output voltage are in the predefined range, the PWR_GOOD signal is set to HIGH. Green LED Will turn ON as soon as PWR_GOOD signal is set to HIGH Derating Guideline Refer to IPC 9592B and Delta Internal Guideline OR-ing Redundant operation with active circuit sharing, see Application Note “Redundant operation”, p. 10 SDA, SCL for I2C Internal 10 kΩ pull-up resistor to internal 3.3 V IMA-x400-xx-ZNPLI IMA-x400-xx-ZNPLY Remote On/Off Pin 1) J3 Pin 10 (REMOTE ON/OFF) REMOTE ON/OFF (J3 Pin 10) and 5VSB_RTN (J3 Pin 3 or J3 Pin 4 or J3 Pin 7) Main DC Output REMOTE ON/OFF (J3 Pin 10) and 5VSB_RTN (J3 Pin 3 or J3 Pin 4 or J3 Pin 7) Main DC Output Shorted OFF Shorted ON Open ON Open OFF 1) Logic can be switched with PMBus™ Data sheet IMA x400 Power Supply Series V2.0 2016-08-09 4 |
Similar Part No. - IMA-x400-48-ZNPLI |
|
Similar Description - IMA-x400-48-ZNPLI |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |