Back Button QS3.241 Datasheet HTML 5Page - PULS GmbH QS3.241 Datasheet HTML 6Page - PULS GmbH QS3.241 Datasheet HTML 7Page - PULS GmbH QS3.241 Datasheet HTML 8Page - PULS GmbH QS3.241 Datasheet HTML 9Page - PULS GmbH QS3.241 Datasheet HTML 10Page - PULS GmbH QS3.241 Datasheet HTML 11Page - PULS GmbH QS3.241 Datasheet HTML 12Page - PULS GmbH QS3.241 Datasheet HTML 13Page - PULS GmbH Next Button
Zoom Inzoom in Zoom Outzoom out
 9 / 25 page
background image
QS3.241
Q-Series
24V, 3.4A, SINGLE PHASE INPUT
8. EFFICIENCY AND POWER LOSSES
AC 100V
AC 120V
AC 230V
Efficiency
typ.
87.1%
88.7%
90.0%
at 24V, 3.4A
Average efficiency *)
typ.
88.9%
89.9%
88.3%
25% at 0.85A, 25% at 1.7A,
25% at 2.55A. 25% at 3.4A
Power losses
typ.
0.9W
1.0W
2.1W
at 24V, 0A
typ.
12.1W
10.4W
9.1W
at 24V, 3.4A
*)
The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25%
of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100%
of the nominal load for the rest of the time.
Fig. 8-1
Efficiency vs. output current at 24V,
typ
Fig. 8-2
Losses vs. output current at 24V, typ.
Efficiency
0.5
1.0
3.5A
87
88
89
90
Output Current
91
92%
120V
ac
100
Vac
230Vac
86
2.0
3.0
1.5
2.5
Power Losses
0
0.5
3.5A
0
2
4
6
8
10
12W
120Vac
100Vac
1.01.5
2.02.53.0
230Vac
Output Current
Fig. 8-3
Efficiency vs. input voltage at 24V,
3.4A, typ.
Fig. 8-4
Losses vs. input voltage at 24V, 3.4A,
typ.
Efficiency
85
120
155
190
225 260Vac
86
87
88
89
Input Voltage
90
91
92%
Power Losses
0
3
6
9
12
15
18W
85
120
155
190
225 260Vac
Input Voltage
Nov. 2011 / Rev. 2.1 DS-QS3.241-EN
All parameters are specified at 24V, 3.4A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0
Germany
9/25


Html Pages

1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23  24  25 


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn