Electronic Components Datasheet Search |
|
QS40.241 Datasheet(PDF) 9 Page - PULS GmbH |
|
QS40.241 Datasheet(HTML) 9 Page - PULS GmbH |
9 / 28 page QS40.241 Q-Series 24V, 40A, SINGLE PHASE INPUT 8. DC-OK RELAY CONTACT This feature monitors the output voltage, which is produced by the power supply itself. It is independent of a back-fed voltage from a unit connected in parallel to the power supply output. Contact closes As soon as the output voltage reaches 90% of the adjusted output voltage. Contact opens As soon as the output voltage dips more than 10% below the adjusted output voltage. Short dips will be extended to a signal length of 250ms. Dips shorter than 1ms will be ignored. Contact re-closes As soon as the output voltage exceeds 90% of the adjusted voltage. Contact ratings max 60Vdc 0.3A, 30Vdc 1A, 30Vac 0.5A resistive load min 1mA at 5Vdc min. permissible load Isolation voltage See dielectric strength table in section 21. Fig. 8-1 DC-ok relay contact behavior 250ms 0.9* V ADJ < 1ms 10% open V OUT = VADJ open closed closed > 1ms 9. SHUT-DOWN INPUT This feature allows a switch-off of the output of the power supply with a signal switch or an external voltage. The shut-down occurs immediately while the turn-on is delayed up to 350ms. In a shut-down condition, the output voltage is <2V and the output power is <0.5W. The voltage between different minus pole output terminals must be below 1V when units are connected in parallel. In a series operation of multiple power supplies only wiring option “A” with individual signal switches is allowed. Please note: - Option C requires a current sink capability of the voltage source. Do not use a blocking diode. - The shut-down function has no safety feature included. Fig. 9-1 Activation of the shut-down input 15 16 OFF: linked ON : open Shut- down Input Option A: 15 16 OFF: I > 0.3mA ON : I < 0.1mA Shut- down Input Option B: - (via open collector) I n.c. 15 16 OFF: U < 1V ON : U = 4 -29V Shut- down Input Option C: - (via external voltage + U n.c. Oct. 2014 / Rev. 1.2 DS-QS40.241-EN All parameters are specified at 24V, 40A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 9/28 |
Similar Part No. - QS40.241 |
|
Similar Description - QS40.241 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |