Electronic Components Datasheet Search
  English  ▼

Delete All
ON OFF
ALLDATASHEET.COM

X  

Preview PDF Download HTML

LCD-E3 Datasheet(PDF) 1 Page - Gamewell-FCI by Honeywell

Part No. LCD-E3
Description  Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System
Download  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  GAMEWELL-FCI [Gamewell-FCI by Honeywell]
Direct Link  http://www.gamewell-fci.com
Logo GAMEWELL-FCI - Gamewell-FCI by Honeywell

LCD-E3 Datasheet(HTML) 1 Page - Gamewell-FCI by Honeywell

  LCD-E3 Datasheet HTML 1Page - Gamewell-FCI by Honeywell LCD-E3 Datasheet HTML 2Page - Gamewell-FCI by Honeywell LCD-E3 Datasheet HTML 3Page - Gamewell-FCI by Honeywell LCD-E3 Datasheet HTML 4Page - Gamewell-FCI by Honeywell LCD-E3 Datasheet HTML 5Page - Gamewell-FCI by Honeywell  
Zoom Inzoom in Zoom Outzoom out
 1 / 5 page
background image
GAMEWELL-FCI
12 Clintonville Road, Northford, CT 06472-1610 USA • Tel: (203) 484-7161 • Fax: (203) 484-7118
Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Gamewell-FCI for their use.
©2014 by Honeywell International Inc. All rights reserved.
www.gamewell-fci.com
9020-0613 Rev. M page 1 of 5
E3 Series®
Broadband System
Intelligent, Networked, Multi-Channel Fire Alarm Control
and Emergency Voice Evacuation System
APPROVED
Class 1
Class 2
High Rise
City of
Chicago
Approved
City of
Denver
Approved
7165-1703:125
FDNY #: 6175
COA # 231-06-E
MEA
Approved
3025415
FM
SIGNALING
S1869
Description
The Gamewell-FCI, E3 Series® Broadband System
includes the NetSOLO® Broadband System. Like the Net-
SOLO Broadband System, the E3 Series Broadband is of
modular design and allows a wide range of configurations
from two basic sub-assemblies. These sub-assemblies
form an integrated, distributed fire alarm system that
includes audio evacuation and fire command capability.
The network communication transmits all fire alarm, audio
evacuation, voice paging, and fire fighter communications.
This System can be used as a component of the following
E3 Series Systems:
• E3 Series Broadband Voice Evacuation System
• E3 Series Combined Fire and Mass Notification System
The E3 Series Broadband is a revolutionary advance in
fire detection and emergency voice evacuation system
design. E3 Series Broadband employs proven technology
and expands it to accomplish emergency multi-channel
voice evacuation, two-way fire fighter communications,
and building control applications, all over a single pair of
wires or fiber-optic cable.
It is a true peer-to-peer, token ring passing, networked sys-
tem capable of supporting up to 64 individual nodes. In
addition, the Addressable Node Expander (ANX) board
expands the network to 122 nodes. All system status, con-
trol-by-event sequences, audio voice paging, and fire
fighter telephone signals are sent between nodes over a
single pair of wires or fiber-optic cable.
Each E3 Series Broadband node can be spaced along the
network a maximum distance of 3,000 feet (914.4 m) over
an unshielded, twisted-pair of wires or fiber-optic cable
with up to 8dB loss. Built-in isolation at each node permits
Style 4, 6, and 7 network configurations.
The E3 Series Broadband is simple to configure for any
project requirement. A complete E3 Series Broadband
application can be assembled from the following types of
nodes; the ILI-E3/ILI95-E3 Series, ANX, the INCC Com-
mand Center, and the INX Transponder.
The E3 Series Broadband System is capable of the most
sophisticated sequences of operations.
E3 Series® and NetSOLO® are registered trademarks of Honeywell International Inc.
UL® is a registered trademark of Underwriters Laboratories Inc
Features
• IBC Seismic Certified.
• Listed under UL® Standard 864, 9th Edition.
• Listed under UL Standard UL2572 for Mass Notification.
• UL Listed for smoke control (dedicated and
non-dedicated) when properly configured.
• FM/UL Listed for Pre-action/Deluge use.
• All communication signals and control-by-event
sequences over a single pair of twisted, unshielded
wires or fiber-optic cable.
• Distributed architecture, including Style 7 wiring
configurations, allow system components to continue
normal operation with no loss of function during single
line fault conditions.
• Integrates INX transponders and INCC command cen-
ters to create a complete audio evacuation system with
up to 122 nodes.
• Redundant command centers with microphone and fire
fighter’s handset are easily configured by adding INCCs.
• Uses state-of-the-art digital signal processor (DSP)
technology for efficient audio compression and filtering.
• Provides up to 150 watts of audio power from 3 AM-50
Series amplifiers with an additional 50 watts of standby
power in each Intelligent Network Transponder (INX).
E3 Series Broadband


Html Pages

1  2  3  4  5 


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn