2 / 6 page Electronic circuit protector REX12 Electronic circuit protector REX12 www.e-t-a.de 2 1646 4 Fail-safe element IN: 1 A fail-safe IN: 1 A integral IN: 2 A fail-safe IN: 2 A blade fuse IN: 3 A fail-safe IN: 3.15 A adjusted to IN: 4 A fail-safe IN: 4 A related current rating IN IN: 6 A fail-safe IN: 6.3 A IN: 8 A fail-safe IN: 8 A IN: 10 A fail-safe IN: 10 A IN: 2 A / 2 A fail-safe IN: 2 A / 2 A IN: 4 A / 4 A fail-safe IN: 4 A / 4 A IN: 6 A / 6 A fail-safe IN: 6.3 A / 6.3 A Voltage drop in load circuit at IN and at IN 70% between LINE+ and LOAD+ IN: 1 A typically 180 mV IN: 70% typically 125 mV IN: 2 A typically 110 mV IN: 70% typically 80 mV IN: 3 A typically 120 mV IN: 70% typically 85 mV IN: 4 A typically 115 mV IN: 70% typically 80 mV IN: 6 A typically 170 mV IN: 70% typically 110 mV IN: 8 A typically 160 mV IN: 70% typically 105 mV IN: 10 A typically 180 mV IN: 70% typically 120 mV Operating voltage OFF at typically UB < 16.0 V monitoring ON at typically UB > 17.5 V with regard to low voltage with automatic ON and OFF switching Switch-on delay - with power ON channel 1: typically 100 ms channel 2: typically 200 ms - when switching on via channel 1: typically 5 ms ON/OFF momentary channel 2: typically 100 ms switch or - after undervoltage channel 1: typically 5 ms channel 2: typically 5 ms Disconnection of - manually on the device with the load circuit ON/OFF momentary switch - after an overload / short circuit disconnection with storage (no automatic reset) - temporarily at undervoltage - at no operating voltage Switch-on of load circuit - momentary switch device can only be switched on ON/OFF when operating voltage is applied - applying the device starts up with the condition operating voltage last stored Reset function a blocked load output (blocked by overload / short circuit) can externally be reset by the ON/OFF momentary switch Leakage current in load typically < 1 mA circuit in OFF condition Capacitive loads up to 20,000 µF Free-wheeling diode external free-wheeling circuit at inductive load (rating according to load) Parallel connection of not allowed several load outputs Status output Status indication REX12-T minus switching signal output group signalling is implemented in connection with EM12-T supply module Screw terminals LOAD+ Push-in terminal PT 2.5 0.14 mm2...2.5 mm2, flexible Stripping length 8 mm...10 mm Dimensions (w x h x d) 12.5 x 98,5 x 80 mm Mass REX12-TA1-xxx 1-channel approx. 57 g REX12-TA2-xxx 2-channel approx. 58 g Technical data (Tamb = +23 °C, UB = DC 24 V) General data Housing material moulded Mounting symmetrical rail to EN 60715-35x7.5 Ambient temperature -25 °C...+60 °C (without condensation, cf. EN 60204-1) Storage temperature -40 °C...+70 °C Mounting temperature +5 °C…+60 °C Humidity 96 hrs / 95 % RH 40 °C to IEC 60068-2- 78-Cab, climate class 3K3 to EN 60721 Vibration 3 g test to IEC 60068-2-6, test Fc Degree of protection (IEC 60529, DIN VDE 0470) IP30 EMC requirements noise emission EN 61000-6-3 (EMC directive, CE logo) susceptibility: EN 61000-6-2 Insulation co-ordination (IEC 60934) 0.5 kV / pollution degree 2 Dielectric strength max. DC 30 V (load circuit) Insulation resistance n/a, only electronic disconnection (OFF condition) Approvals CE logo, UL 2367, File # E306740, (UL60947 / UL 508, File # E...) under preparation Technical data (Tamb = +23 °C, UB = DC 24 V) Type REX12 Electronic circuit protector with PT connection technology Mounting method T rail mounting Design A 1 load output terminal per channel, fixed current ratings xA or xA/xA Number of channels 1 1 channel 2 2 channels Version 1 without physical isolation Signal input 0 without signal input Signal output: 7 status output Operating voltage DC 24 V voltage rating DC 24 V Current ratings 1 A (only 1-channel) 2 A (only 1-channel) 3 A (only 1-channel) 4 A (only 1-channel) 6 A (only 1-channel) 8 A (only 1-channel) 10 A (only 1-channel) 2 A/2 A (only 2-channel) 4 A/4 A (only 2-channel) 6 A/6 A (only 2-channel) REX12 - T A 1 - 1 0 7 - DC24V - 10 A example of 1-channel REX12 - T A 2 - 1 0 7 - DC24V - 6 A / 6 A example of 2-channel Ordering number code - REX12-T Preferred types Standard current ratings (A) REX12-TA1 2 4 6 10 2/2 4/4 6/6 REX12-TA1-107-DC24V- x x x x REX12-TA2 2 4 6 10 2/2 4/4 6/6 REX12-TA2-107-DC24V- x x x Preferred types |
Similar Part No. - REX12-TA1-107-DC24V-4A |
|
Similar Description - REX12-TA1-107-DC24V-4A |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |