Electronic Components Datasheet Search |
|
SLM300PS24-T Datasheet(PDF) 1 Page - XP Power Limited |
|
SLM300PS24-T Datasheet(HTML) 1 Page - XP Power Limited |
1 / 2 page Specification 300-600 Watts • Industrial (SL) & Medical (SLM) Versions • Output Voltages from 12 V to 96 V • Power Factor Corrected • Remote On/Off • Current Share • Power Fail Signal • Overtemperature Protection SL & SLM Series Input Input Voltage • 90-264 VAC (125-360 VDC) Input Frequency • 44-66 Hz Input Current • 300 W models: 4.4 A at 90 VAC 1.8 A at 230 VAC 600 W models: 8.9 A at 90 VAC 3.5 A at 230 VAC Inrush Current • 100 A at 230 VAC Power Factor • 0.9 typical Earth Leakage Current • SL models: <2.5 mA at 264 VAC/50 Hz SLM models: <100 µA at 264 VAC/50 Hz Input Protection • 10 A HRC fuse Output Output Voltage • See table Output Voltage Trim • See table Initial Set Accuracy • ±1% max Minimum Load • No minimum load required Start Up Delay • 600 ms max Start Up Rise Time • 150 ms max Hold Up Time • 18 ms min Line Regulation • <0.5% V min to V max Load Regulation • <2.0% for a 0-100% load change Transient Response • 2% max deviation, recovery to within 0.25% in 1 ms for a 10% load change Ripple & Noise • 1% pk-pk max, 20 MHz BW Overvoltage Protection • 120% approx Vnom Overtemperature • Fitted to 600 W models only, Protection recycle mains to reset Overload Protection • 110% typical, constant current Short Circuit Protection • Constant current Temperature • 0.02%/˚C Coefficient Remote On/Off • Output inhibited by shorting ROF pin to 0 V Current Share • Allows up to 5 units to share within 5% xppower.com General Efficiency • 85% typical Isolation • 6000 VDC Input to Output (Y caps disconnected) 2200 VDC Input to Ground 2200 VDC Output to Chassis Switching Frequency • 30-35 kHz PFC, 45-55 kHz PWM Signals • AC OK - TTL compatible signal is high with reference to 0 V when AC is OK MTBF • 105 kHrs typical per MIL-HDBK-217E at +20 ˚C. Consult office for each model Environmental Operating Temperature • -20 ˚C to +70 ˚C, derate from +40 ˚C to 50% power at +70 ˚C Operating Humidity • 90% RH, non-condensing Storage Temperature • -25 ˚C to +85 ˚C Operating Altitude • 3000 m Shock • Non operating. 100 mm drop on to chassis face Vibration • Operating 5-50 Hz 0.05 mm pk-pk, 50-100 Hz 0.025 mm pk-pk Airflow Direction • Where fitted fans blow air into the unit EMC & Safety Emissions • EN55022, level B conducted EN55022, level A radiated Harmonic Currents • EN61000-3-2, class A Voltage Flicker • EN61000-3-3 ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, level 3 Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms Perf Criteria A, B, B Safety Approvals • SL: UL60950, CSA22.2 No.60950 SLM: UL2601-1, CSA C22.2 No.60601-1 |
Similar Part No. - SLM300PS24-T |
|
Similar Description - SLM300PS24-T |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |