04
Function
E6175A
E6176A
E6177A & E6177B
E6178B
Path resistance from
power bus to load card
connect
0.25 Ω maximum
0.4 Ω maximum
0.5 Ω maximum
0.030 Ω typical,
0.075 Ω maximum
Load path relay
operate/release time
10/8 msec typical,
16/10 msec maximum,
30 cps maximum
10/8 msec typical,
16/10 msec maximum,
30 cps maximum
3.3/2.4 msec typical,
8/8 msec maximum,
10 cps maximum
15/10 msec typical,
20 cps maximum
without load, 6 cpm
maximum with
rated load
Peak voltage to earth
60 V continuous
500 V maximum
transient, non-switching
(delays to < 60 V in
200 mS)
60 V continuous
500 V maximum
transient, non-switching
(delays to < 60 V in
200 mS)
60 V continuous
500 V maximum
transient, non-switching
(delays to < 60 V in
200 mS)
60 V continuous
Load carry/switching
current (per channel)
7.5 A maximum non-
switching, continuous
7.5 A maximum non-
switching, continuous
3 A maximum
30 A maximum (1)
Load carry peak current
(non-switching)
15 A maximum,
(< 100 msec, < 2% duty
cycle)
15 A maximum,
(< 100 msec, < 2% duty
cycle)
6 A maximum,
(< 100 msec, < 2% duty
cycle)
200 A maximum,
(< 100 mS, < 2%
duty cycle (1))
Load switching power
150 W maximum,
resistive load
150 W maximum,
resistive load
60 W maximum,
resistive load
500 W maximum @
25 Vdc maximum
resistive load;
100 W maximum @
40 Vdc maximum
resistive load
Load switching voltage
60 V maximum
60 V maximum
60 V maximum
40 V maximum, V*I
not to exceed load
switching power (2)
Minimum permissible
load
1 mA, 1 V
1 mA, 1 V
10 uA, 10 mV DC
N/A
Basic current sense
accuracy with standard
0.05 W sense resistor
0.1% maximum
0.1% maximum
0.1% maximum
(for E6177B only)
0.1% maximum
(1)
One channel at a time. Special accessories required to support multi-channel 30 A load switching at any one time.
(2)
Exclusive of load
Switching Speciications
Keysight Single-Load Load Cards Speciications


Html Pages

1  2  3  4  5  6  7 


Datasheet Download




Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn