A1365LKTTN-1-T Datasheet(HTML) 18 Page - Allegro MicroSystems |
18 / 32 page ![]() Low-Noise, High-Precision, Programmable Linear Hall-Effect Sensor IC With High-Bandwidth (120 kHz) Analog Output and Integrated Fault Comparator A1365 18 Allegro MicroSystems, LLC 115 Northeast Cutoff Worcester, Massachusetts 01615-0036 U.S.A. 1.508.853.5000; www.allegromicro.com Transient Fault Release Time (tTFRL) As the Over Field Fault condition goes away, tTFRL is the time interval between a) when the recovering input crosses the DC Fault Switchpoint and when the FAULT pin reaches 80% of its final value. Note that the DC Fault Switchpoint will be impacted by the programmed Fault Hysteresis Level (VFHSYT). 80 (%) t Transient Fault Release Time DC Fault Switchpoint Applied Magnetic Field Transducer Output V FAULT (t ) TFRL Figure 8: Transient Fault Release Time (tTFRL) |
|