LM93CIMT Datasheet(PDF) 5 Page - National Semiconductor (TI)

[Old version datasheet] Texas Instruments acquired National semiconductor.
Part # LM93CIMT
Description  Hardware Monitor with Integrated Fan Control for Server Management
Download  92 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  NSC [National Semiconductor (TI)]
Direct Link  http://www.national.com
Logo NSC - National Semiconductor (TI)

LM93CIMT Datasheet(HTML) 5 Page - National Semiconductor (TI)

  LM93CIMT Datasheet HTML 1Page - National Semiconductor (TI) LM93CIMT Datasheet HTML 2Page - National Semiconductor (TI) LM93CIMT Datasheet HTML 3Page - National Semiconductor (TI) LM93CIMT Datasheet HTML 4Page - National Semiconductor (TI) LM93CIMT Datasheet HTML 5Page - National Semiconductor (TI) LM93CIMT Datasheet HTML 6Page - National Semiconductor (TI) LM93CIMT Datasheet HTML 7Page - National Semiconductor (TI) LM93CIMT Datasheet HTML 8Page - National Semiconductor (TI) LM93CIMT Datasheet HTML 9Page - National Semiconductor (TI) Next Button
Zoom Inzoom in Zoom Outzoom out
 5 / 92 page
background image
Table of Contents (Continued)
15.6 ERROR STATUS REGISTERS ............................................................................................................. 27
15.6.1 ASF Mode ........................................................................................................................................ 27
15.7 MASKING, ERROR STATUS AND ALERT ........................................................................................... 27
15.8 LAYOUT AND GROUNDING ................................................................................................................ 27
15.9 THERMAL DIODE APPLICATION ......................................................................................................... 27
15.9.1 Accuracy Effects of Diode Non-Ideality Factor ................................................................................ 28
15.9.2 PCB Layout for Minimizing Noise .................................................................................................... 28
15.10 FAN CONTROL ................................................................................................................................... 28
15.10.1 Automatic Fan Control Algorithm ................................................................................................... 28
15.10.2 Fan Control Temperature Resolution ............................................................................................ 30
15.10.3 Zone 1-4 to PWM1-2 Binding ........................................................................................................ 31
15.10.4 Fan Control Duty Cycles ............................................................................................................... 31
15.10.5 Alternate PWM Frequencies .......................................................................................................... 31
15.10.6 Fan Control Priorities ..................................................................................................................... 31
15.10.7 PWM to 100% Conditions ............................................................................................................. 31
15.10.8 VRDx_HOT Ramp-Up/Ramp-Down .............................................................................................. 32
15.10.9 PROCHOT Ramp-Up/Ramp-Down ............................................................................................... 32
15.10.10 Manual PWM Override ................................................................................................................ 32
15.10.11 Fan Spin-Up Control .................................................................................................................... 32
15.11 XOR TREE TEST ................................................................................................................................ 33
16.0 Registers .................................................................................................................................................. 34
16.1 REGISTER WARNINGS ....................................................................................................................... 34
16.2 REGISTER SUMMARY TABLE ............................................................................................................. 34
16.3 FACTORY REGISTERS 00h–3Fh ........................................................................................................ 40
16.3.1 Register 00h
XOR Test ................................................................................................................. 40
16.3.2 Register 01h
SMBus Test ............................................................................................................. 40
16.3.3 Register 3Eh
Manufacturer ID ...................................................................................................... 40
16.3.4 Register 3Fh
Version/Stepping ..................................................................................................... 40
16.4 BMC ERROR STATUS REGISTERS 40h–47h .................................................................................... 41
16.4.1 Register 40h
B_Error Status 1 ...................................................................................................... 41
16.4.2 Register 41h
B_Error Status 2 ...................................................................................................... 42
16.4.3 Register 42h
B_Error Status 3 ...................................................................................................... 42
16.4.4 Register 43h
B_Error Status 4 ...................................................................................................... 43
16.4.5 Register 44h
B_P1_PROCHOT Error Status ............................................................................... 43
16.4.6 Register 45h
B_P2_PROCHOT Error Status ............................................................................... 44
16.4.7 Register 46h
B_GPI Error Status .................................................................................................. 44
16.4.8 Register 47h
B_Fan Error Status .................................................................................................. 45
16.5 HOST ERROR STATUS REGISTERS .................................................................................................. 45
16.5.1 Register 48h
H_Error Status 1 ...................................................................................................... 45
16.5.2 Register 49h
H_Error Status 2 ...................................................................................................... 46
16.5.3 Register 4Ah
H_Error Status 3 ..................................................................................................... 47
16.5.4 Register 4Bh
H_Error Status 4 ..................................................................................................... 48
16.5.5 Register 4Ch
H_P1_PROCHOT Error Status ............................................................................... 49
16.5.6 Register 4Dh
B_P2_PROCHOT Error Status ............................................................................... 50
16.5.7 Register 4Eh
H_GPI Error Status ................................................................................................. 51
16.5.8 Register 4Fh
H_Fan Error Status ................................................................................................. 52
16.6 VALUE REGISTERS ............................................................................................................................. 52
16.6.1 Registers 50–53h
Unfiltered Temperature Value Registers ......................................................... 52
16.6.2 Registers 54–55h
Filtered Temperature Value Registers ............................................................. 52
16.6.3 Register 56–65h
A/D Channel Voltage Registers ........................................................................ 53
16.6.4 Register 67h
Current P1_PROCHOT ........................................................................................... 53
16.6.5 Register 68h
Average P1_PROCHOT .......................................................................................... 54
16.6.6 Register 69h
Current P2_PROCHOT ........................................................................................... 54
16.6.7 Register 6Ah
Average P2_PROCHOT ......................................................................................... 54
16.6.8 Register 6Bh
GPI State ................................................................................................................. 55
16.6.9 Register 6Ch
P1_VID .................................................................................................................... 55
16.6.10 Register 6Dh
P2_VID .................................................................................................................. 55
16.6.11 Register 6E–75h
Fan Tachometer Readings .............................................................................. 56
16.7 LIMIT REGISTERS ................................................................................................................................ 57
16.7.1 Registers 78–7Fh
Temperature Limit Registers ........................................................................... 57
16.7.2 Registers 80–83h
Fan Boost Temperature Registers .................................................................. 57
www.national.com
5


Similar Part No. - LM93CIMT

ManufacturerPart #DatasheetDescription
logo
Texas Instruments
LM93CIMT TI1-LM93CIMT Datasheet
1Mb / 95P
[Old version datasheet]   Hardware Monitor with Integrated Fan Control for Server Management
LM93CIMT/NOPB TI1-LM93CIMT/NOPB Datasheet
1Mb / 95P
[Old version datasheet]   Hardware Monitor with Integrated Fan Control for Server Management
LM93CIMTX/NOPB TI1-LM93CIMTX/NOPB Datasheet
1Mb / 95P
[Old version datasheet]   Hardware Monitor with Integrated Fan Control for Server Management
More results

Similar Description - LM93CIMT

ManufacturerPart #DatasheetDescription
logo
Texas Instruments
LM93 TI1-LM93 Datasheet
1Mb / 95P
[Old version datasheet]   Hardware Monitor with Integrated Fan Control for Server Management
LM94 TI1-LM94_15 Datasheet
1Mb / 112P
[Old version datasheet]   Hardware Monitor with PI Loop Fan Control for Server Management
logo
National Semiconductor ...
LM94 NSC-LM94 Datasheet
697Kb / 24P
   TruTherTM Hardware Monitor with PI Loop Fan Control for Server Management
LM96000 NSC-LM96000 Datasheet
695Kb / 28P
   Hardware Monitor with Integrated Fan Control
logo
List of Unclassifed Man...
ASC7611 ETC2-ASC7611 Datasheet
508Kb / 40P
   HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
logo
National Semiconductor ...
LM85 NSC-LM85 Datasheet
261Kb / 26P
   Hardware Monitor with Integrated Fan Control
logo
List of Unclassifed Man...
ASC7621 ETC2-ASC7621 Datasheet
574Kb / 50P
   HARDWARE MONITOR WITH INTEGRATED FAN CONTROL
logo
Texas Instruments
LM96000 TI1-LM96000 Datasheet
1Mb / 40P
[Old version datasheet]   Hardware Monitor with Integrated Fan Control
logo
National Semiconductor ...
LM96194 NSC-LM96194 Datasheet
529Kb / 24P
   TruTherm??Hardware Monitor with PI Fan Control for Workstation Management
logo
Feature Integration Tec...
F71858 FINTEK-F71858_09 Datasheet
1Mb / 65P
   Hardware KBC with ACPI, Temp. and Fan Control
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com