Voltage Transducer AV100 Series
For the electronic measurement of voltages : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high voltage)
and the secondary circuit (electronic circuit).
Electrical data
Primary nominal
Primary Voltage
R.m.s. voltage for AC
Type
R.m.s or DC voltage
measuring range
isolation test1)
(50 Hz/1min)
V
PN (V)
V
Pmax (V)
V
d
(kV)
50
± 75
3.3
AV 100-50
125
± 187.5
3.3
AV 100-125
150
± 225
3.3
AV 100-150
250
± 375
3.3
AV 100-250
500
± 750
3.3
AV 100-500
750
± 1125
4.3
AV 100-750
1000
± 1500
5.5
AV 100-1000
1500
± 2250
6.5
AV 100-1500
P
V
ˆ
Not measurable overload
2 x V
Pmax (1s/h)
V
DC
R
M
Measuring resistance
R
M min
R
M max
@ V
C=11.4V
0
47
@ V
C=22.8V
0
184
I
SN
Secondary nominal r.m.s. current
50
mA
V
C
Supply voltage (± 5 %)
DC ± 12 .. 24
V
I
c
Current consumption
50+I
S
mA
Max Common mode voltage
U
HT+ + U HT- ≤ 4.2 kV
DC
and
U
HT+ - U HT-≤ VPMAX
V
e
R.m.s. voltage for partial discharge
1.1 2)
kV
extinction @ 10pC
2.2 3)
kV
Accuracy - Dynamic performance data
X
G
Overall Accuracy @ V
PN , TA = + 25°C
± 0.7
%
X
G
Overall Accuracy @ V
PN , TA = - 25 .. + 70°C
± 1.5
%
X
G
Overall Accuracy @ V
PN , TA = - 40 .. + 85°C
± 1.7
%
ε
L
Linearity @ T
A = 25°C
< 0.1
%
I
O
Offset current @ V
P = 0, TA = 25°C
± 0.15
mA
t
r
Response time @ 10 % of V
Pmax
Between 10 and 13 µs
f
Frequency bandwidth (- 3 dB)
DC .. 13
kHz
General data
T
A
Ambient operating temperature
- 40 .. + 85
°C
T
S
Ambient storage temperature
- 50 .. + 90
°C
m
Mass
375
g
Standards
EN 50155
EN 50124-1
NFF16101/2
Notes : 1) Between primary and secondary
Features
Insulated plastic case recognized
according to UL 94-V0.
Included primary resistor
Advantages
Low power
Excellent accuracy
Very good linearity
Low thermal drift
Low response time
High bandwidth
High immunity to external
interference
Low disturbance in common mode.
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Power supplies for welding
applications
.
V
PN = 50...1500 V
030523/4
2) For models AV 100-50 to 750
3) For models AV 100-1000 & AV 100-1500
LEM Components


Html Pages

1  2 


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn