Electronic Components Datasheet Search |
|
BCC400PS03 Datasheet(PDF) 1 Page - XP Power Limited |
|
BCC400PS03 Datasheet(HTML) 1 Page - XP Power Limited |
1 / 2 page Specification 200 400 Watts • Baseplate cooled • Wide Operating Temperature Range • ETSI, EMC and Environmental Compliant • Parallel Operation • Remote On/Off • Low Temperature Option • 3 Year Warranty BCC Series Input Input Voltage • 90-264 VAC Input Frequency • 47-63 Hz Input Current • 3 A max at 90 VAC (BCC200) 6 A max at 90 VAC (BCC400) Inrush Current • 60 A at 264 VAC +25 °C cold start Power Factor • >0.9 Earth Leakage Current • <1.5 mA at 230 VAC Input Protection • Internal T10 A/250 V fuse Output Output Power • See table Output Voltage • See table Output Voltage Trim • 60% to 110% Vnom Initial Set Accuracy • ±1% nominal Minimum Load • No minimum load Hold Up Time • 10 ms min Line Regulation • ±0.5% Load Regulation • See table Ripple & Noise • <1% pk-pk, 20 MHz bandwidth Overvoltage Protection • 105-140% Vnom (3.3 V version 130-166%) Overtemperature • Shuts down at +115 °C baseplate Protection temperature, recycle mains to reset Overload Protection • 102-140% constant current limiting with auto recovery Temperature • 0.05%/°C Coefficient Remote Sense • Compensates for lead drops of up to 500 mV Remote On/Off • A logic ‘0’ on the Remote On/Off connection electronically disables the output Current Share • Up to 3 power supplies can be connected in parallel sharing within 10%, total output power derates by 10% xppower.com General Efficiency • 80% typical Isolation • 3000 VAC Input to Output 1500 VAC Input to Ground 500 VAC Output to Ground Switching Frequency • PWM 360 kHz typ, PFC 90 kHz typ MTBF • 160 kHrs to MIL-HDBK-217F at 25 °C, GB Environmental Operating Temperature • -20 °C to +70 °C, with baseplate maintained below +83 °C utilizing system cooling, -40 °C option available - add suffix ‘-L’ to model number Cooling • Conduction via 6mm baseplate Operating Humidity • 20-95% RH, non-condensing. Units can be conformally coated for high humidity environments - add suffix ‘-E’ Storage Temperature • -40 °C to +85 °C Shock & Vibration • 2 g 10 min/1 cycle, 10 Hz to 500 Hz, 60 mins each axis EMC & Safety Emissions • EN55022, level B conducted & level A radiated Harmonic Currents • EN61000-3-2, EN61000-3-3 ESD Immunity • EN61000-4-2, level 3 Perf Criteria A Radiated Immunity • EN61000-4-3, 3 V/m Perf Criteria A EFT/Burst • EN61000-4-4, level 3 Perf Criteria A Surge • EN61000-4-5, level 3 Perf Criteria A Conducted Immunity • EN61000-4-6, level 3 Perf Criteria A Dips & Interruptions • EN61000-4-11, 30% 10 ms, 60% 100 ms, 100% 5000 ms, Perf Criteria A, B, B Safety Approvals • UL60950-1: CSA22.2 No. 60950-1-03, CE Mark LVD, EN60950-1 |
Similar Part No. - BCC400PS03 |
|
Similar Description - BCC400PS03 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |