2 / 10 page ![]() www.sensirion.com Version 4 – May 2014 2/10 Sensor Performance Relative Humidity123 Parameter Condition Value Units Resolution 12 bit 0.04 %RH Accuracy tolerance 1 typ 3.0 %RH max see Figure 2 %RH Repeatability 0.1 %RH Hysteresis 1 %RH Nonlinearity <0.1 %RH Response time 2 63% 8 s Operating Range extended 3 0 to 100 %RH Long Term Drift 4 Typ. < 0.25 %RH/yr Figure 2 Typical and maximal tolerance at 25°C for relative humidity. For extensive information see Users Guide, Sect. 1.2. Electrical Specification Parameter Condition min typ max Units Supply Voltage, VDD 2.1 3.0 3.6 V Supply Current, IDD 5 180 µA Power Dissipation 5 0.54 mW PWM frequency 40 °C 108 120 132 Hz Temperature drift of PWM frequency -0.07 -0.12 Hz/°C Measurement Frequency 2 Hz Switch RH/T on SDA SCL up RH; SCL down T Table 1 Electrical specification. For absolute maximum values see Chapter 4.1 of Users Guide. 1 Accuracies are tested at Outgoing Quality Control at 25°C and 3.0V. Values exclude hysteresis and long term drift and are applicable to non-condensing environments only. 2 Time for achieving 63% of a step function, valid at 25°C and 1 m/s airflow. 3 Normal operating range: 0-80%RH, beyond this limit sensor may read a reversible offset with slow kinetics (+3%RH after 60h at humidity >80%RH). For more details please see Section 1.1 of the Users Guide. Temperature456 Parameter Condition Value Units Resolution 14 bit 0.01 °C Accuracy tolerance 1 typ 0.3 °C max see Figure 3 °C Repeatability 0.1 °C Operating Range extended 3 -40 to 125 °C Response Time 6 63% 5 to 30 s Long Term Drift 7 Typ. < 0.02 °C/yr Figure 3 Typical and maximal temperature accuracy tolerance Packaging Information Sensor Type Packaging Quantity Order Number SHT20P Tape & Reel 1500 1-100745-01 Tape & Reel 5000 1-100746-01 This datasheet is subject to change and may be amended without prior notice. 4 Typical value for operation in normal RH/T operating range. Max. value is < 0.5 %RH/y. Value may be higher in environments with vaporized solvents, out- gassing tapes, adhesives, packaging materials, etc. For more details please refer to Handling Instructions. 5 Values of Supply Current and Power Dissipation are based upon fixed VDD = 3.0V and T = 25°C. 6 Response time depends on heat conductivity of sensor substrate. 7 Max. value is < 0.04°C/y. ± 0 ± 2 ± 4 ± 6 ± 8 ± 10 0 10 20 30 40 50 60 70 80 90 100 ΔRH (%RH ) Relative Humidity (%RH) maximum accuracy typical accuracy ± 0.0 ± 0.5 ± 1.0 ± 1.5 ± 2.0 -40 -20 0 20 40 60 80 100 120 ΔT ( C) Temperature (°C) maximum accuracy typical accuracy |
|