622Mbps, 3.3V Clock-Recovery and
Data-Retiming IC with Limiting Amplifier
6
_______________________________________________________________________________________
Pin Description
32
CFILT
RSSI Filter Capacitor Input
30
ADI+
Positive Analog Data Input, 622.08Mbps serial-data stream
29
ADI-
Negative Analog Data Input, 622.08Mbps serial-data stream
28
INSEL
Input Select. Connect to GND to select digital data inputs or VCC for analog data inputs.
27
DDI-
Negative Digital Data Input, PECL, 622.08Mbps serial-data stream
26
DDI+
Positive Digital Data Input, PECL, 622.08Mbps serial-data stream
23
FIL+
Positive Filter Input. PLL loop filter connection.
22
FIL-
Negative Filter Input. PLL loop filter connection.
20
PHADJ+
Positive Phase-Adjust Input. Used to optimally align internal PLL phase. Attach to VCC if not used.
19
PHADJ-
Negative Phase-Adjust Input. Used to optimally align internal PLL phase. Attach to VCC if not used.
NAME
FUNCTION
1
OLC+
Positive Offset-Correction Loop Capacitor Input
2
OLC-
Negative Offset-Correction Loop Capacitor Input
PIN
3
RSSI
Received-Signal-Strength Indicator Output
4, 8, 16,
24, 25
GND
Supply Ground
9, 12, 15,
18, 21, 31
VCC
Positive Supply Voltage
7
LOP
Loss-of-Power Output, TTL. Limiting amplifier loss-of-power monitor. Asserts high when input signal
is below threshold set by VTH.
6
VTH
Voltage Threshold Input. Threshold voltage for loss-of-power monitor. Attach to VCC if LOP function
is not used.
5
INV
Op Amp Inverting Input. Attach to ground if op amp is not used.
17
LOL
Loss-of-Lock Output, TTL. PLL loss-of-lock monitor, active low (see
Design Procedure).
14
SDO+
Positive Serial-Data Output, PECL, 622.08Mbps
13
SDO-
Negative Serial-Data Output, PECL, 622.08Mbps
11
SCLKO+
Positive Serial-Clock Output, PECL, 622.08MHz. SDO+ is clocked out on the rising edge of SCLKO+.
10
SCLKO-
Negative Serial-Clock Output, PECL, 622.08MHz. SDO- is clocked out on the falling edge of SCLKO-.


Html Pages

1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16 


Datasheet Download




Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn