HC-5509B Datasheet(PDF) 4 Page - Intersil Corporation

Part No. HC-5509B
Description  SLIC Subscriber Line Interface Circuit
Download  10 Pages
Scroll/Zoom Zoom In 100% Zoom Out
Maker  INTERSIL [Intersil Corporation]
Homepage  http://www.intersil.com/cda/home
Logo 

HC-5509B Datasheet(HTML) 4 Page - Intersil Corporation

 
Zoom Inzoom in Zoom Outzoom out
 4 / 10 page
background image
4
Ring Trip Detection Threshold
VRING = 105VRMS, fRING = 20Hz
-
10
-
mA
Ring Trip Detection Period
-
100
150
ms
Dial Pulse Distortion
-
0.1
0.5
ms
Relay Driver Outputs
On Voltage VOL
IOL (PR) = 60mA, IOL (RD) = 30mA
-
0.2
0.5
V
Off Leakage Current
VOH = 13.2V
-
±10
±100
µA
TTL/CMOS Logic Inputs (F0, F1, RS, TEST, PRI)
Logic ‘0’ VIL
-
-
0.8
V
Logic ‘1’ VIH
2.0
-
5.5
V
Input Current (F0, F1, RS, TEST, PRI)
0V
≤ VIN ≤ 5V
-
-
±100
µA
Logic Outputs
Logic ‘0’ VOL
ILOAD = 800µA
-
0.1
0.5
V
Logic ‘1’ VOH
ILOAD = 40µA
2.7
-
-
V
Power Dissipation On Hook
Relay Drivers Off
-
200
-
mW
IB+
VB+ = +5.25V, VB- = -58V, RLOOP =
--
6
mA
IB-
VB+ = +5.25V, VB- = -58V, RLOOP =
-6
-
-
mA
UNCOMMITED OP AMP PARAMETERS
Input Offset Voltage
-
±5-
mV
Input Offset Current
-
±10
-
nA
Differential Input Resistance
(Note 3)
-
1
-
M
Output Voltage Swing
RL = 10kΩ
-
±3-
VP-P
Small Signal GBW
(Note 3)
-
1
-
MHz
NOTES:
1. Absolute maximum ratings are limiting values, applied individually, beyond which the serviceability of the circuit may be impaired.
Functional operability under any of these conditions is not necessarily implied.
2. May Be Extended to 1900
Ω With Application Circuit.
3. These parameters are controlled by design or process parameters and are not directly tested. These parameters are characterized upon
initial design release, upon design changes which would affect these characteristics, and at intervals to assure product quality and
specification compliance.
Electrical Specifications
Unless Otherwise Specified, Typical Parameters are at TA = +25
oC, Min-Max Parameters are Over
Operating Temperature Range, VB- = -48V, VB+ = +5V, AG = DG = BG = 0V. All AC Parameters are
specified at 600
Ω 2-Wire Terminating Impedance. (Continued)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNITS
Specifications HC-5509B3999-003


Html Pages

1  2  3  4  5  6  7  8  9  10 


Datasheet Download




Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn