  HT-0102 Datasheet HTML 1Page - FCI connector HT-0102 Datasheet HTML 2Page - FCI connector HT-0102 Datasheet HTML 3Page - FCI connector HT-0102 Datasheet HTML 4Page - FCI connector HT-0102 Datasheet HTML 5Page - FCI connector HT-0102 Datasheet HTML 6Page - FCI connector HT-0102 Datasheet HTML 7Page - FCI connector HT-0102 Datasheet HTML 8Page - FCI connector HT-0102 Datasheet HTML 9Page - FCI connector Next Button
Zoom Inzoom in Zoom Outzoom out
 4 / 10 page
background image
ELECTRONICS
FCI Electronics
Manual Part No. 144000-001
Issued: Date (10/24/94)
Page 4 of 10
Rev. 03/08/01 ECR V103118
Revision B
K\DCU\Manuals
D. Specifications (continued)
Strip Length of Insulation:
•Latch Housing and
Discrete Applications ................... 3.81-4.32 mm
(0.150-0.170 in.)
Wire Barrel Crimp Height:
•Single Wire (28-32 AWG)
Or Double Wires
(30-32 AWG) ............................... 0.61-0.66 mm
(0.024-0.026 in.)
•Single Wire (22-26 AWG)
Or Double Wires
(26-28 AWG) ............................... 0.76-0.81 mm
(0.030-0.032 in.)
Insulation Barrel Crimp Height:
•"A" Side (28-32 AWG)
Latch Housing and
Discrete Applications ................. 1.75 mm
(0.069 in.) Max. Dia.
•“B" Side (22-26 AWG)
Latch Housing and
Discrete Applications ................... 1.75 mm
(0.069 in.) Max. Dia.
Male Pin Terminals:
•Loose Piece....................................... 22-32 AWG
NOTE
Loose piece terminals have different part
numbers than reeled terminals
II. OPERATION
A. Operating Procedures
1. Hold the hand tool so that the lever is on the left.
With your index finger, push and hold the terminal
holder in its forward position (see Figure 2).
NOTE
When inserting a terminal into the terminal holder
you will notice a slight drag (interference) on the
terminal. The drag is caused by the spring ball
plunger (see Figure 13 item no. 21) applying
downward pressure on the pin end of the terminal.
This downward pressure helps to orient and hold
the terminal in the terminal holder until crimped
.
2. Insert the pin end of the terminal, with “U” shaped
barrels up, into the terminal holder and against the
pin shoulder. While holding the terminal against
the shoulder, release the terminal holder. This
ensures that the terminal remains in the proper
position while moving over the anvil.
Figure 2. Positioning Terminal for Crimping
CAUTION
If the terminal and the tooling are not compatible,
damage to the tooling could result. If you wish to use a
terminal with a part number other than the one that
was ordered for the HT-0102 check with your
distributor or FCI Electronics to be sure that the new
terminal number is compatible with your hand tool.
WARNING
To prevent hand injury, keep fingers from between
the upper and lower tooling and from between the
lever and handle when closing hand tool.
PDM: Rev:B
Released
STATUS:
Printed: Dec 20, 2002


Html Pages

1  2  3  4  5  6  7  8  9  10 


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn