Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.COM

X  

HMR2300-D20-232-DEMO Datasheet(PDF) 7 Page - Honeywell Accelerometers

Part # HMR2300-D20-232-DEMO
Description  Smart Digital Magnetometer
Download  12 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  HONEYWELL-ACC [Honeywell Accelerometers]
Direct Link  http://www.inertialsensor.com
Logo HONEYWELL-ACC - Honeywell Accelerometers

HMR2300-D20-232-DEMO Datasheet(HTML) 7 Page - Honeywell Accelerometers

Back Button HMR2300-D20-232-DEMO Datasheet HTML 3Page - Honeywell Accelerometers HMR2300-D20-232-DEMO Datasheet HTML 4Page - Honeywell Accelerometers HMR2300-D20-232-DEMO Datasheet HTML 5Page - Honeywell Accelerometers HMR2300-D20-232-DEMO Datasheet HTML 6Page - Honeywell Accelerometers HMR2300-D20-232-DEMO Datasheet HTML 7Page - Honeywell Accelerometers HMR2300-D20-232-DEMO Datasheet HTML 8Page - Honeywell Accelerometers HMR2300-D20-232-DEMO Datasheet HTML 9Page - Honeywell Accelerometers HMR2300-D20-232-DEMO Datasheet HTML 10Page - Honeywell Accelerometers HMR2300-D20-232-DEMO Datasheet HTML 11Page - Honeywell Accelerometers Next Button
Zoom Inzoom in Zoom Outzoom out
 7 / 12 page
background image
HMR2300
www.honeywell.com
7
COMMAND INPUTS
A simple command set is used to communicate with the HMR2300. These commands can be automated; or typed in real-
time while running communication software programs, such a windows hyperterminal.
Command
Inputs(1)
Response(2)
Bytes(3)
Description
Format
*ddWE *ddA
*ddWE *ddB
ASCII_ON¬
BINARY_ON¬
9
10
ASCII
– Output Readings in BCD ASCII Format (Default)
Binary
– Output Readings in Signed 16-bit Bianary
Format
Output
*ddP
*ddC
Esc
{x, y, z reading}
{x, y, z stream}
{stream stops}
7 or 28
...
0
P = Polled
– Output a Single Sample (Default)
C = Continuous
– Output Readings at Sample Rate
Escape Key
– Stops Continuous Readings
Sample Rate
*ddWE *ddR=nnn
OK¬
3
Set Sample Rate to nnn Where:
Nnn = 10, 20, 25, 30, 40, 50, 60, 100, 123, or 154
Samples/sec (Default = 20)
Set/Reset
Mode
*ddWE *ddTN
*ddWE *ddTF
*ddWE *ddT
S/R_ON¬
S/R_OFF¬
{Toggle}
7
8
7 or 8
S/R Mode: TN
– ON = Auto S/R Pulses (Default)
TF
– OFF = Manual S/R Pulses
*ddT Toggles Command (Default = On)
Set/Reset
Pulse
*dd]S
*dd]R
*dd]
SET¬
RST¬
{Toggle}
4
4
4
] Character
– Single S/R: ]S -> SET = Set Pulse
]R -> RST = Reset Pulse
Toggle Alternates Between Set and Reset Pulse
Device ID
*99ID=
*ddWE *ddID=nn
ID=_nn¬
OK¬
7
3
Read Device ID (Default = 00)
Set Device ID Where nn = 00 to 98
Baud Rate
*99WE *99!BR=S
*99WE *99!BR=F
OK¬
BAUD_9600¬
OK¬
BAUD=_19,200¬
14
14
Set Baud Rate to 9600 bps (Default)
Set Baud Rate to 19,200 bps
(8 bits, no parity, 1 stop bit)
Zero Reading
*ddWE *ddZN
*ddWE *ddZF
*ddWE *ddZR
ZERO_ON¬
ZERO_OFF¬
{Toggle}
8
9
8 or 9
Zero Reading Will Store and Use Current as a Negative
Offset so That the Output Reads Zero Field
*ddZR Toggles Command
Average
Readings
*ddWE *ddVN
*ddWE *ddVF
*ddWE *ddV
AVG_ON¬
AVG_OFF¬
{Toggle}
7
8
7 or 8
The Average Reading for the Current Sample X(N) is:
Xavg=X(N)/2 + X(N-1)/4 + X(N-2)/8 + X(N-3)/16 + ...
*ddV Toggles Command
Re-Enter
Response
*ddWE *ddY
*ddWE *ddN
OK¬
OK¬
3
3
Turn the “Re-Enter” Error Response ON (*ddY) or OFF
(*ddN). OFF is Recommended for RS-485 (Default = ON)
Query Setup
*ddQ
{See Desc.}
62-72
Read Setup Parameters. Default: ASCII, POLLED, S/R
ON, ZERO OFF, AVG OFF, R ON, ID=00, 20 sps
Default Settings
*ddWE *ddD
OK¬
BAUD=_9600¬
14
Change All Command Parameter Settings to Factory
Default Values
Restore Settings
*ddWE *ddRST
OK¬
BAUD=_9600¬
or
BAUD=_19,200¬
14
16
Change All Command Parameter Settings to the Last
User Stored Values in the EEPROM
Serial Number
*dd#
SER#_nnnn¬
22
Output the HMR2300 Serial Number
Software Version
*ddF
S/W_vers:_
nnnn¬
27
Output the HMR2300 Software Version Number
Hardware
Version
*ddH
H/W_vers:_
nnnn¬
19
Output the HMR2300 Hardware Version Number
Write Enable
*ddWE
OK¬
3
Activate
a
Write
Enable.
This
is
required
before
commands: Set Device ID, Baud Rate, and Store
Parameters.
Store
Parameters
*ddWE *ddSP
DONE¬
OK¬
8
This writes all parameter settings to EEPROM. These
values will be automatically restored upon power-up.
Too Many
Characters
Wrong Entry
Re-enter¬
9
A command was not entered properly or 10 characters
were typed after an asterisk (*) and before a <cr>.
Missing WE
Entry
Write Enable Off
WE_OFF¬
7
This error response indicates that this instruction requires
a write enable command immediately before it.
(1) All inputs must be followed by a <cr> carriage return, or Enter, key. Either upper or lower case letters may be used. The device ID
(dd) is a decimal number between 00 and 99. Device ID = 99 is a global address for all units.
(2) The “¬” symbol is a carriage return (hex 0D). The “_” sign is a space (hex 20). The output response will be delayed from the end of
the carriage return of the input string by 2 msec (typ.), unless the command sent as a global device ID = 99.


Similar Part No. - HMR2300-D20-232-DEMO

ManufacturerPart #DatasheetDescription
logo
Honeywell Solid State E...
HMR2300 HONEYWELL-HMR2300 Datasheet
596Kb / 12P
   Smart Digital Magnetometer
HMR2300R HONEYWELL-HMR2300R Datasheet
156Kb / 8P
   THREE-AXIS STRAPDOWN MAGNETOMETER
HMR2300R-422 HONEYWELL-HMR2300R-422 Datasheet
156Kb / 8P
   THREE-AXIS STRAPDOWN MAGNETOMETER
HMR2300R-485 HONEYWELL-HMR2300R-485 Datasheet
156Kb / 8P
   THREE-AXIS STRAPDOWN MAGNETOMETER
More results

Similar Description - HMR2300-D20-232-DEMO

ManufacturerPart #DatasheetDescription
logo
Honeywell Solid State E...
HMR2300 HONEYWELL-HMR2300 Datasheet
596Kb / 12P
   Smart Digital Magnetometer
logo
Freescale Semiconductor...
MAG3110 FREESCALE-MAG3110_12 Datasheet
369Kb / 28P
   Three-Axis, Digital Magnetometer
MAG3110 FREESCALE-MAG3110 Datasheet
327Kb / 23P
   3-Axis, Digital Magnetometer
logo
Rohm
BM1422AGMV ROHM-BM1422AGMV Datasheet
2Mb / 29P
   3-Axis Digital Magnetometer IC
logo
NXP Semiconductors
MAG3110 NXP-MAG3110 Datasheet
470Kb / 30P
   Xtrinsic MAG3110 Three-Axis, Digital Magnetometer
Rev. 9.2, 02/2013
logo
Melexis Microelectronic...
MLX90392 MELEXIS-MLX90392 Datasheet
2Mb / 40P
   3D Magnetometer
logo
List of Unclassifed Man...
IST8310 ETC-IST8310 Datasheet
251Kb / 9P
   3D Magnetometer
Version 1.2
logo
Melexis Microelectronic...
MLX90393 MELEXIS-MLX90393 Datasheet
618Kb / 27P
   Micropower Triaxis Magnetometer
logo
Bosch Sensortec GmbH
BMM350 BOSCH-BMM350 Datasheet
328Kb / 3P
   High-performance magnetometer
Version_1.0_102022
logo
PCE Instruments.
PCE-MFM2400 PCE-PCE-MFM2400 Datasheet
331Kb / 2P
   Magnetometer PCE-MFM 2400
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com