RoboClock
CY7B994V
CY7B993V
Document #: 38-07127 Rev. *E
Page 9 of 14
Operating Current
ICCI
Internal Operating
Current
CY7B993V
VCC = Max., fMAX
[7]
–250
mA
CY7B994V
–
250
mA
ICCN
Output Current
Dissipation/Pair[8]
CY7B993V
VCC = Max.,
CLOAD = 25 pF,
RLOAD = 50Ω at VCC/2,
fMAX
–40
mA
CY7B994V
–
50
mA
Electrical Characteristics Over the Operating Range (continued)
Parameter
Description
Test Conditions
Min.
Max.
Unit
Capacitance
Parameter
Description
Test Conditions
Min.
Max.
Unit
CIN
Input Capacitance
TA = 25°C, f = 1 MHz, VCC = 3.3V
5
pF
Switching Characteristics Over the Operating Range[9, 10, 11, 12, 13]
Parameter
Description
CY7B993/4V-2
CY7B993/4V-5
Unit
Min.
Max.
Min.
Max.
fin
Clock Input Frequency
CY7B993V
12
100
12
100
MHz
CY7B994V
24
200
24
200
MHz
fout
Clock Output Frequency
CY7B993V
12
100
12
100
MHz
CY7B994V
24
200
24
200
MHz
tSKEWPR
Matched-Pair Skew[14, 15]
–
200
–
200
ps
tSKEWBNK
Intrabank Skew[14, 15]
–
200
–
250
ps
tSKEW0
Output-Output Skew (same frequency and phase, rise to rise, fall to
fall)[14, 15]
–
250
–
550
ps
tSKEW1
Output-Output Skew (same frequency and phase, other banks at
different frequency, rise to rise, fall to fall)[14, 15]
–
250
–
650
ps
tSKEW2
Output-Output Skew (invert to nominal of different banks, compared
banks at same frequency, rising edge to falling edge aligned, other
banks at same frequency)[14, 15]
–
250
–
700
ps
tSKEW3
Output-Output Skew (all output configurations outside of tSKEW1and
tSKEW2.)
[14, 15]
–
500
–
800
ps
tSKEWCPR
Complementary Outputs Skew (crossing to crossing, complementary
outputs of the same bank)[14, 15, 16, 17]
–
200
–
300
ps
tCCJ1-3
Cycle-to-Cycle Jitter (divide by 1 output frequency,
FB = divide by 1, 2, 3)
–
150
–
150
ps
Peak-
Peak
tCCJ4-12
Cycle-to-Cycle Jitter (divide by 1 output frequency,
FB = divide by 4, 5, 6, 8, 10, 12)
–
100
–
100
ps
Peak-
Peak
tPD
Propagation Delay, REF to FB Rise
–250
250
–500
500
ps
Notes:
7.
ICCI measurement is performed with Bank1 and FB Bank configured to run at maximum frequency (fNOM = 100 MHz for CY7B993V, fNOM = 200 MHz for
CY7B994V), and all other clock output banks to run at half the maximum frequency. FS and OUTPUT_MODE are asserted to the HIGH state.
8.
This is dependent upon frequency and number of outputs of a bank being loaded. The value indicates maximum ICCN at maximum frequency and maximum
load of 25 pF terminated to 50
Ω at V
CC/2.
9.
This is for non-three level inputs.
10. Assumes 25-pF max. load capacitance up to 185 MHz. At 200 MHz the max. load is 10 pF.
11.
Both outputs of pair must be terminated, even if only one is being used.
12. Each package must be properly decoupled.
13. AC parameters are measured at 1.5V unless otherwise indicated.
14. Test Load CL= 25 pF, terminated to VCC/2 with 50Ω up to185 MHz and 10-pF load to 200 MHz.
15. SKEW is defined as the time between the earliest and the latest output transition among all outputs for which the same phase delay has been selected when
all outputs are loaded with 25 pF and properly terminated up to 185 MHz. At 200 MHz the max load is 10 pF.
16. Complementary output skews are measured at complementary signal pair intersections.
17. Guaranteed by statistical correlation. Tested initially and after any design or process changes that may affect these parameters.