5 / 10 page www.irf.com 5 ATW28XXS Series Table II. Electrical Performance Characteristics - continued Notes to Specifications ATW2812S 1 Parameter guaranteed by line and load regulation tests. 2 Bandwidth guaranteed by design. Tested for 20kHz to 2.0MHz. 3 Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry, appearing as a short circuit during turn-on. 4 Parameter shall be tested as part of design characterization and after design or process changes. Thereafter, parameters shall be guaranteed to the limits specified in Table II. 5 An overload is that condition with a load in excess of the rated load but less than that necessary to trigger the short circuit protection and is the condition of maximum power dissipation. 6 Load step transition time between 2.0 µs and 10µs. 7 Recovery time is measured from the initiation of the transient to where V OUT has returned to within ±1.0% of VOUT at 50% load. 8 Input step transition time between 2.0 µs and 10µs. 9 Turn-on delay time measurement is for either a step application of power at the input or the removal of ground signal from the inhibit pin (pin 2) while power is applied to the input. Test Symbol Conditions -55°C ≤ Tc ≤ +125°C Vin = 28 Vdc ±5%, CL = 0 unless otherwise specified Group A Subgroups Device Types Limits Unit Min Max Recovery time step transient load changes 6, 7 TTLOAD 1250mA to/from 2500mA 4 All 100 µs 5,6 200 0mA to 1250mA 4 All 5.0 ms 5,6 10 Output response to VOTLINE Input step 18V to/ from 4,5,6 All -1000 +1000 mVpk Transient step 40V dc, Line changes IOUT = 2500mA 4, 8 Recovery time TTLINE Input step 18V to/ from 4,5,6 All 500 µs Transient step 40V dc Line changes IOUT = 2500mA 4, 7, 8 Turn on overshoot VTonOS IOUT = 0 and 2500mA 4,5,6 All 600 mVpk Turn on delay TonD IOUT = 0 and 2500mA 9 4,5,6 All 12 ms Load fault recovery 4, 9 TrLF 4,5,6 All 12 ms |
Similar Part No. - ATW2812SES-MSTR |
|
Similar Description - ATW2812SES-MSTR |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |