Electronic Components Datasheet Search |
|
CSNM191-003 Datasheet(PDF) 3 Page - Honeywell Accelerometers |
|
CSNM191-003 Datasheet(HTML) 3 Page - Honeywell Accelerometers |
3 / 5 page PERFORMANCE DATA Definition Acurrent transducer based on the principle of magnetic compensation. It provides electronic measurement of DC, AC, pulsed currents and their combinations with galvanic isolation between the primary (high current) and secondary circuits. Electrical Data CSNL181 - XXX CSNM191 - XXX Nominal current (In) : 300 Arms : 500 Arms Measuring range : 0 to ±600 A : 0 to ±1000 A Measuring Resistance (Rm) : Rm min Rm max : Rm min Rm max with ±15V at ±300 A.t max : 0 ohm 50 ohm at ±500 A.t max : 0 ohm 50 ohm at ±600 A.t max : 0 ohm 10 ohm at ±1000 A.t max : 0 ohm 5 ohm Nominal analogue output current : 150 mA : 100 mA Turns Ratio : 1/2000 : 1/5000 Overall accuracy at +25°C : ±0.5% on In : ±0.5% of In Supply Voltage : ±12V to 18V (±5%) : ±12V to ±18V (±5%) Isolation between primary and secondary : 7.5 kV rms/50 Hz/1 min : 6.0 kV rms/50 Hz/1 min Accuracy - Dynamic Performance Zero offset current at +25°C : Max ±0.3 mA : Max ±0.2 mA Thermal drift of offset current, between 0°C to +70°C : Typ ±0.3 mA; Max ±0.5 mA : Typ ±0.2 mA; Max ±0.3 mA Linearity : better than ±0.1% : better than ±0.1% Response time : better than 500nS : better than 1µs di/dt accurately followed : better than 50 A/µs : better than 50 A/µs Bandwidth : DC to 150 KHz : DC to 100 KHz General data Operating temperature : -40°C to +85°C (-40°F to +185°F) : -40°C to +85°C (-40°F to +185°F) Storage temperature : -40°C to +90°C (-40°F to +194°F) : -40°C to +90°C (-40°F to +194°F) Current consumption : Typ 14mA(±18V) + output current : Typ 14mA(±18V) + output current Secondary internal resistance : 25 ohm (at 70°C) : 50 ohm (at 70°C) Sensor Housing : Insulated plastic case (Bayblend FR1468) : Insulated plastic case (Bayblend FR1468) Signal sense : a positive output current is obtained on : a positive output current is obtained on terminal O/Pwhen the primary current terminal O/Pwhen the primary current flows in the direction of the arrow flows in the direction of the arrow EMC : EN50081-2, EN 50082-2 : EN50081-2, EN 50082-2 Honeywell • Sensing and Control 2 PERSONALINJURY • DO NOTUSE these products as safety or emergency stop devices, or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING Electrical Connection Termination + - ov Rm OUTPUT + - O/P 300A: Supply Voltage ±12V to ±18V 500A: Supply Voltage ±12V to ±18V O/PMeasured output signal |
Similar Part No. - CSNM191-003 |
|
Similar Description - CSNM191-003 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |