Electronic Components Datasheet Search
  English  ▼
ALLDATASHEET.COM

X  

FCX-MVL-F-AC Datasheet(PDF) 1 Page - Fujikura Ltd.

Part # FCX-MVL-F-AC
Description  Oxygen sensor module
Download  3 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  FUJIKURA [Fujikura Ltd.]
Direct Link  http://www.fujikura.co.jp
Logo FUJIKURA - Fujikura Ltd.

FCX-MVL-F-AC Datasheet(HTML) 1 Page - Fujikura Ltd.

  FCX-MVL-F-AC Datasheet HTML 1Page - Fujikura Ltd. FCX-MVL-F-AC Datasheet HTML 2Page - Fujikura Ltd. FCX-MVL-F-AC Datasheet HTML 3Page - Fujikura Ltd.  
Zoom Inzoom in Zoom Outzoom out
 1 / 3 page
background image
Oxygen sensor module
FCX-M Data sheet
FCX-M series
Model
■Specifications
Item
FCX-MP-F-AC
FCX-MQ-F-AC
FCX-MV-F
FCX-MV-F-AC
FCX-MW-F
FCX-MW-F-AC
FCX-MWGP-2A-F
FCX-MEP2-F
FCX-MEP2-F-AC
Measurement range
50 to 1000ppmO2
0.05 to 1 %O2
0.1 to 25 %O2
0.1 to 95 %O2
75 to 95 %O2
0.1 to 25 %O2
Accuracy
+/-5%FS
+/-5%FS
+/-1%FS
+/-0.5%FS
+/-2%O2
+/-1%FS
50 to 1000 mV
50 to 1000 mV
1 to 250 mV
0 to 2669 mV
1235 to 2669 mV
4 to 20 mA
Output (Logarithmic)
Vout=-999.5x10
3
x LN 1-
Vout= -99.5x10
3
x LN 1-
Vout= -891x LN 1-
Output= -57x
LN 1-
+4
Response time
3
90sec. (for 90% value)
30sec. (for 90% value)
30sec. (for 90% value)
Power supply
4
DC5+/-0.2V
DC5+0.1/-0.25V
DC12+/-3V
Power consumption
5W max.
4W max.
3W
Operating temperature
-10 to 50 deg.C
0 to 60 deg.C
-10 to 50 deg.C
Operating humiditiy
5
0 to 85%RH
40 to 85%RH
0 to 85%RH
Dimensions
50x16x104 mm
40x23x80 mm
45x20x52 mm
Weight
Approx. 65grams
Approx. 40grams
Approx. 40grams
Item
FCX-MVL-F
FCX-MVL-F-AC
FCX-MWL-F
FCX-MWL-F-AC
Measurement range
0.1 to 25 %O2
0.1 to 95 %O2
Accuracy
+/-1%FS
+/-1%FS
1 to 250 mV
1 to 950 mV
Output (Linear)
Vout= 10xO2%
Response time
3
30sec. (for 90% value)
Power supply
4
DC5+/-0.2V
Power consumption
5W max.
Operating temperature
-10 to 50 deg.C
Operating humiditiy
5
0 to 85%RH
Dimensions
50x38x104 mm
Weight
Approx. 120grams
1 Depends on operating environment.
2 Annual calibration or maintenance still recommended.
3 From 10 to 90% step change.
4 Regurated DC power supply.The current capacity must be 1A.
5 Without vapour condensation.
■Features
High accuracy
Long life (More than 3 years in normal air) *1
Continues calibration and maintenance not required *2
Calibration gas not required
From ppm to 95%O2, wide measurement range
No interfarance to media
No pressure dependence
■Applications
Oxygen concentrator
Nitrogen purifier
Alarm for oxygen shortage
Culture oven ro Incubator
Combustion control
Soldering system
Instruction for use ;
1. Sensor modules are calibrated with N2-O2 balance gases. Other gases may affect
the sensor performance by increase errors.
2. Do NOT separate the sensing element from the circuit board and lead wires length
must be remained unchanged.
3. Do NOT use in harsh environmental conditions containing halogen atoms(F,Cl,Br) ,
SOx ,Nox or H2S which make the sensor inferior in a short time.
4. Flammable gases ,such as H2 ,CO ,methane or Alcohol make a big error. And please
note that the temperature at the sensing part goes uo to 450 degrees C during the
operation,which may exceed the flash point and cause explosion.
5. Silicone gas or vapour including Siloxane also make the sensor inferior in a short time.
6. Dust or oil mist cause failures of the products,errors or a slow response. They must be
eliminated with a filter.
7. Water drop's contact may give a damage to sensor. It must be eliminated with a filter.
8. Temperature at the sensor mesh surface reach 50~80 degrees C during operation.
Please take precautions against burning yourseif.
9. A strong shock such as drop may cut internal wires or break the sensor pellet which is
made of ceramic. Do NOT apply a shock of 10G or more to the sensor.
10. The warranty period is one year from the ex-factory date. This warranty does NOT
apply to the sensors as follows ;
1) There are any defects to faults caused by an improper dealing during the
transpotation after Fujikura has delivered the sensor to place where the buyer had
instructed.
2) There are any defects or faults caused by the buyer's misuses ,abuse or neglect.
3) The buyer fixed or remake the sensors.
4) There are any indentical or consequential damages which are given in the usage.
5) There are any defects or faults caused by natural disasters such as life ,earthquake,
flood or thunder.
11. Fujikura's oxygen sensors are NOT developed ,designed ,manufactured ,sold ,
intended or authorized for use as components in systems intended for the surgical
implant into the body ,other applications intended to support or sustain life ,fail-safe
applications in which the failures ,breakages or where misused of the sensors could
create a situation where personal injury or death ,explosion or fire ,or serious social
damage may occur. Fujikura and its subcontractors and distributors accept NO
responsibility the buyer's selection and use of Fujikura's oxygen sensors without
Fujikura's written approval in any such unintended or unauthorized and situation where
personal injury or death ,explosion or fire ,or serious social damage may occur.
12. A fail-safe design is strongly required when customers use the sensor in
medecal applications or alarm systems for oxygen shortage even except above.
If you have any questions regarding technical issues or specifications,
please contact us.
Note ; Please read above instructions before using the sensor.
Fujikura reserves right to change specifications without notice.
Fujikura Ltd. Sensor Department
5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072
E-mail : sensor@fujikura.co.jp
ppmO2
106
%O2
100
%O2
100
%O2
100
RoHS compliance


Similar Part No. - FCX-MVL-F-AC

ManufacturerPart #DatasheetDescription
logo
PANDUIT CORP.
FCX-12-10BY PANDUIT-FCX-12-10BY Datasheet
133Kb / 3P
   QuickNet MTP Fiber Optic Cassettes
FCX-12-10Y PANDUIT-FCX-12-10Y Datasheet
133Kb / 3P
   QuickNet MTP Fiber Optic Cassettes
FCX-12-3SY PANDUIT-FCX-12-3SY Datasheet
133Kb / 3P
   QuickNet MTP Fiber Optic Cassettes
FCX-12-3Y PANDUIT-FCX-12-3Y Datasheet
133Kb / 3P
   QuickNet MTP Fiber Optic Cassettes
FCX-24-10BY PANDUIT-FCX-24-10BY Datasheet
133Kb / 3P
   QuickNet MTP Fiber Optic Cassettes
More results

Similar Description - FCX-MVL-F-AC

ManufacturerPart #DatasheetDescription
logo
List of Unclassifed Man...
O2-E2 ETC-O2-E2 Datasheet
294Kb / 2P
   Oxygen Sensor
logo
Figaro Engineering Inc.
SK-25F FIGARO-SK-25F Datasheet
333Kb / 2P
   Figaro Oxygen Sensor
logo
Zhengzhou Winsen Electr...
ME2-O2-D20 WINSEN-ME2-O2-D20 Datasheet
523Kb / 4P
   Electrochemical Oxygen Sensor
logo
Figaro Engineering Inc.
KDS-25B FIGARO-KDS-25B Datasheet
292Kb / 2P
   Maxell Dissolved Oxygen Sensor
logo
Sensortechnics GmbH
ZBXYA025M0 SENSORTECHNICS-ZBXYA025M0 Datasheet
239Kb / 5P
   Oxygen sensor interface boards
logo
Honeywell Accelerometer...
KGZ10-SP HONEYWELL-ACC-KGZ10-SP Datasheet
227Kb / 4P
   Oxygen Sensors
logo
Sensortechnics GmbH
XYA1S SENSORTECHNICS-XYA1S Datasheet
66Kb / 4P
   Oxygen sensors
logo
Fuji Electric
EDS3-62H FUJI-EDS3-62H Datasheet
110Kb / 4P
   PARAMAGNETIC OXYGEN ANALYZER
EDS3-69F FUJI-EDS3-69F Datasheet
150Kb / 4P
   PARAMAGNETIC OXYGEN ANALYZER
EDS3-115C FUJI-EDS3-115C Datasheet
81Kb / 4P
   PARAMAGNETIC OXYGEN ANALYZER
More results


Html Pages

1 2 3


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com