Electronic Components Datasheet Search
  English  ▼

Delete All
ON OFF
ALLDATASHEET.COM

X  

Preview PDF Download HTML

CLRC663 Datasheet(PDF) 59 Page - NXP Semiconductors

Part No. CLRC663
Description  Contactless reader IC
Download  132 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  NXP [NXP Semiconductors]
Direct Link  http://www.nxp.com
Logo NXP - NXP Semiconductors

CLRC663 Datasheet(HTML) 59 Page - NXP Semiconductors

Back Button CLRC663 Datasheet HTML 55Page - NXP Semiconductors CLRC663 Datasheet HTML 56Page - NXP Semiconductors CLRC663 Datasheet HTML 57Page - NXP Semiconductors CLRC663 Datasheet HTML 58Page - NXP Semiconductors CLRC663 Datasheet HTML 59Page - NXP Semiconductors CLRC663 Datasheet HTML 60Page - NXP Semiconductors CLRC663 Datasheet HTML 61Page - NXP Semiconductors CLRC663 Datasheet HTML 62Page - NXP Semiconductors CLRC663 Datasheet HTML 63Page - NXP Semiconductors Next Button
Zoom Inzoom in Zoom Outzoom out
 59 / 132 page
background image
CLRC663
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.3 — 3 April 2012
171133
59 of 132
NXP Semiconductors
CLRC663
Contactless reader IC
8.10.3.15
StoreKeyE2 command
Command (0Fh), Parameter1 (KeyNr), Parameter2(keybyte1), Parameter3(keybyte2),
Parameter4(keybyte3), Parameter5(keybyte4), Parameter6(keybyte5), Parameter7
(keybyte6);
Stores MIFARE Keys into the EEPROM. The key number parameter indicates the first key
(n) in the MKA that will be written. If more than one MIFARE Key is available in the FIFO
then the next key (n+1) will be written as well and so forth until the FIFO is empty. If an
incomplete key (less than 6 bytes) is written into the FIFO, this key will be ignored and will
remain in the FIFO.
Abort condition: Insufficient parameter in FIFO; KeyNr is outside the MKA;
8.10.3.16
GetRNR command
Command (1Ch);
This command is reading Random Numbers from the random number generator of the
CLRC663. The Random Numbers are copied to the FIFO until the FIFO is full.
8.10.3.17
SoftReset command
Command (1Fh);
This command is performing a soft reset. Triggered by this command all the default values
for the register setting will be read from the EEPROM and copied into the register set.


Html Pages

1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23  24  25  26  27  28  29  30  31  32  33  34  35  36  37  38  39  40  41  42  43  44  45  46  47  48  49  50  51  52  53  54  55  56  57  58  59  60  61  62  63  64  65  66  67  68  69  70  71  72  73  74  75  76  77  78  79  80  81  82  83  84  85  86  87  88  89  90  91  92  93  94  95  96  97  98  99  100   ...More


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn