CLRC663
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2012. All rights reserved.
Product data sheet
COMPANY PUBLIC
Rev. 3.3 — 3 April 2012
171133
57 of 132
NXP Semiconductors
CLRC663
Contactless reader IC
Remark: If the bit RxMultiple in the RxModeReg register is set to logic 1, the Receive
command does not terminate automatically. It has to be terminated by activating any other
command in the CommandReg register (see Section 9.17.6 “RxMod”).
8.10.3.7
Transmit command
Command (06h);
The content of the FIFO is transmitted immediately after starting the command. Before
transmitting the FIFO content all relevant register have to be set to transmit data.
This command terminates automatically when the FIFO gets empty. It can be terminated
by any other command written to the command register.
8.10.3.8
Transceive command
Command (07h);
This command transmits data from the FIFO and receives data from the RF field once.
The first action is transmitting and after a transmission the command is changed to
receive a data stream.
Each transmission process starts by writing the command into CommandReg.
Remark: If the bit RxMultiple in register RxModeReg is set to logic 1, this command will
never leave the receiving state, because the receiving will not be cancelled automatically.
8.10.3.9
WriteE2 command
Command (08h), Parameter1 (addressL), Parameter2 (addressH), Parameter3 (data);
This command writes one byte into the EEPROM. If the FIFO contains no data, the
command will wait until the data is available
Abort condition: insufficient parameter in FIFO; Address-parameter outside of range
8.10.3.10
WriteE2PAGE command
Command (09h), Parameter1 (page address), Parameter2 (data0), Parameter3...65
[data1 ..data63];
This command writes up to 64 bytes into the EEPROM.
Abort condition: Insufficient parameters in FIFO; Page address parameter outside of
range.
8.10.3.11
ReadE2 command
Command (0Ah), Parameter1 (addressL), Parameter2 (addressH), Parameter3 (length);
Reads up to 256 bytes from the EEPROM to the FIFO. If a read operation exceeds the
address 1FFFh, the read operation continues from address 0000h.
Abort condition: Insufficient parameter in FIFO; Address parameter outside of range.
8.10.3.12
LoadReg command
Command (0Ch), Parameter1 (EEPROM addressL),Parameter2 (EEPROM addressH),
Parameter3 (RegAdr), Parameter4 (number);


Html Pages

1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23  24  25  26  27  28  29  30  31  32  33  34  35  36  37  38  39  40  41  42  43  44  45  46  47  48  49  50  51  52  53  54  55  56  57  58  59  60  61  62  63  64  65  66  67  68  69  70  71  72  73  74  75  76  77  78  79  80  81  82  83  84  85  86  87  88  89  90  91  92  93  94  95  96  97  98  99  100   ...More


Datasheet Download




Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn