7 / 12 page ![]() 7 Operation parameter Parameter (name) Read/write date setting range Factory default Registor No. Run/Standby switch 0: Run 1: Standby 0 (RUN) 40021 Digital input latch releases command 0: OFF 1: Release latch 0 (OFF) 40022 Digital output latch releases command 0: OFF 1: Release latch 0 (OFF) 40023 Communication parameter Parameter (name) Read/write date setting range Factory default Registor No. RS-485 Parity setting 0: NONE 1: ODD 2: EVEN 0 (NONE) 40111 RS-485 Response interval time 0 to 25 (×20ms) 1 40113 RS-485 Communication permission 0: Read only 1: Read/Write 1 (R/W) 40114 RS-485 Communication speed 0: 9.6kbps 1: 19.2kbps 2: 38.4kbps 3: Forbidden 4: 115.2kbps 1 (9.6kbps) 40115 Enhanced communication module (PUMC) connection 0: PUMC not connected (RS485 Enable) 1: PUMC connected (RS485 Disable) 040116 Configuration parameter Parameter (name) Read/write date setting range Factory default Registor No. FAULT output set value 0: HOLD 1: OFF 0 (HOLD) 40260 Standby output set value 0000 to FFFF 0000 40268 Standby mode setting 0: DI=Input value, DO=Standby output set value 1: DI=All OFF, DO=Standby output set value 0 40270 LED2 Lamp Allocation 0 to 2 1 40222 |
|