  039-6000-100 Datasheet HTML 1Page - Magnetrol International, Inc. 039-6000-100 Datasheet HTML 2Page - Magnetrol International, Inc. 039-6000-100 Datasheet HTML 3Page - Magnetrol International, Inc. 039-6000-100 Datasheet HTML 4Page - Magnetrol International, Inc. 039-6000-100 Datasheet HTML 5Page - Magnetrol International, Inc. 039-6000-100 Datasheet HTML 6Page - Magnetrol International, Inc. 039-6000-100 Datasheet HTML 7Page - Magnetrol International, Inc. 039-6000-100 Datasheet HTML 8Page - Magnetrol International, Inc.  
Zoom Inzoom in Zoom Outzoom out
 3 / 8 page
background image
3
Tuffy Liquid Level Control with Pneumatic Switch
1.0
Installation
This section provides detailed procedures for properly
installing the Tuffy Liquid Level Control.
Caution: If equipment is used in a manner not specified by
manufacturer, protection provided by equipment
may be impaired.
1.1
Unpacking
Unpack the instrument carefully. Inspect all units for dam-
age. Report any concealed damage to the carrier within 24
hours. Check the contents of the packing slip and report
any discrepancies to Magnetrol. Check the nameplate model
number to be sure it agrees with the packing slip and pur-
chase order. Check and record the serial number for future
reference when ordering parts.
Model Number
Serial Number
1.2
Before You Begin
1.2.1 Site Preparation
1. Ensure that the length and inside diameter of the mounting
nozzle are sized correctly to allow for switch actuation at
design levels. Refer to Figure 1.
2. Ensure that the mounting nozzle or coupling is within 3°
of horizontal. If mounting the Tuffy in an external cage,
ensure that the cage is mounted within 3° of horizontal
and that the top/bottom piping is within 3° of vertical in all
directions.
3. Ensure that the area is free of metallic particles which might
be attracted to the magnet holder/counterbalance and inter-
fere with the function of the Tuffy.
1.2.2 Equipment and Tools
No special equipment or tools are required to install the
Tuffy Liquid Level Switch. The following items are recom-
mended:
• Wrenches, flange gaskets and flange bolting appropriate for
process connection(s).
• Pipe wrench
• Level
Figure 1
1/4" NPT
inlet (A)
1/4" NPT
outlet (C)
3.00" maximum
nozzle length
1/4" NPT
inlet (B)
Float must
clear inner
tank wall
Wrench flats
Serial number tag


Similar Part No. - 039-6000-100

ManufacturerPart No.DatasheetDescription
Magnetrol International, Inc.
Magnetrol International...
039-6000-100 MAGNETROL-039-6000-100 Datasheet
152Kb / 4P
   Tuffy Liquid Level Controls with Pneumatic Switch
More results

Similar Description - 039-6000-100

ManufacturerPart No.DatasheetDescription
Magnetrol International, Inc.
Magnetrol International...
039-6000-104 MAGNETROL-039-6000-104 Datasheet
152Kb / 4P
   Tuffy Liquid Level Controls with Pneumatic Switch
T52-1E3N-KOG MAGNETROL-T52-1E3N-KOG Datasheet
283Kb / 24P
   Side Mounting Liquid Level Controls
T31-002N-10A MAGNETROL-T31-002N-10A Datasheet
542Kb / 28P
   Tuffy짰 II Liquid Level Controls with Electric Switches
T3B MAGNETROL-T3B Datasheet
308Kb / 12P
   Tuffy II짰 Liquid Level Controls with Electric Switches
B40-1F30-R1M MAGNETROL-B40-1F30-R1M Datasheet
293Kb / 8P
   B40 Liquid Level Switch
List of Unclassifed Manufacturers
List of Unclassifed Man...
LS-541 ETC2-LS-541 Datasheet
93Kb / 2P
   Liquid level float switch
Magnetrol International, Inc.
Magnetrol International...
TK1-001N-BRC MAGNETROL-TK1-001N-BRC Datasheet
233Kb / 12P
   Side Mounted Liquid Level Float Switch
B75-1B20-KOG MAGNETROL-B75-1B20-KOG Datasheet
215Kb / 8P
   Non-Bleed Switch For Liquid Level Switches
B40-1F30-FKB MAGNETROL-B40-1F30-FKB Datasheet
457Kb / 20P
   Liquid Level Switches
T20-1B2A-9DR MAGNETROL-T20-1B2A-9DR Datasheet
316Kb / 24P
   Liquid Level Switches
More results


Html Pages

1  2  3  4  5  6  7  8 


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz