Electronic Components Datasheet Search |
|
LPF-40D-42 Datasheet(PDF) 1 Page - Mean Well Enterprises Co., Ltd. |
|
LPF-40D-42 Datasheet(HTML) 1 Page - Mean Well Enterprises Co., Ltd. |
1 / 4 page SPECIFICATION MODEL DCVOLTAGE RATEDCURRENT RATEDPOWER OUTPUT LINEREGULATION LOADREGULATION SETUP,RISETIME Note.7 HOLDUP TIME (Typ.) VOLTAGERANGE Note.5 FREQUENCY RANGE POWERFACTOR (Typ.) EFFICIENCY (Typ.) ACCURRENT (Typ.) INPUT INRUSHCURRENT(Typ.) LEAKAGECURRENT WORKINGTEMP. WORKINGHUMIDITY STORAGETEMP.,HUMIDITY TEMP.COEFFICIENT VIBRATION MTBF DIMENSION OTHERS NOTE PACKING OVERCURRENT Note.4 OVERVOLTAGE OVERTEMPERATURE 12V LPF-40D-12 LPF-40D-15 LPF-40D-20 LPF-40D-24 LPF-40D-30 LPF-40D-36 LPF-40D-42 LPF-40D-48 LPF-40D-54 7.2~12V 15V 9~15V 20V 12~20V 24V 14.4~24V 30V 18~30V 36V 21.6~36V 48V 28.8~48V 3.34A 2.67A 2A 1.67A 1.34A 1.12A 0.84A 40.08W 40.08W 40W 40.08W 40.2W 40.32W 40.32W 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p 250mVp-p 250mVp-p 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 4.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2.0% 1.5% 1.0% 0.5% 0.5% 0.5% 0.5% 1000ms,80ms/115VACatfullload1000ms,80ms/230VAC 16ms/230VAC16ms/115VACatfullload 90~305VAC127~431VDC 47~63Hz PF>0.97/115VAC,PF>0.95/230VAC,PF>0.92/277VACatfullload(Pleasereferto"PowerFactorCharacteristic"curve) 84% 85% 86% 87% 88% 88% 89% COLDSTART 75A/230VAC <0.75mA /240VAC 95~108% Protectiontype:Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved -40~+70 (Referto"DeratingCurve") 20~95%RH non-condensing -40~+80 ,10~95%RH 0.03%/ (0~50 ) 10~500Hz,5G12min./1cycle,periodfor72min.eachalongX, Y,Zaxes 394.9Khrsmin.MIL-HDBK-217F(25 ) 162.5*43*32mm(L*W*H) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 0.45Kg;32pcs/15.4Kg/0.93CUFT Protectiontype: Shutdownandlatchoffo/pvoltage,re-powerontorecover RIPPLE&NOISE(max.) Note.2 VOLTAGETOLERANCE Note.3 ENVIRONMENT SAFETY & EMC PROTECTION 90 10 (RTH2) Protectiontype:Shutdowno/pvoltage, re-powerontorecover SHORTCIRCUIT Hiccupmode,recoversautomaticallyafterfaultconditionisremoved. UL8750, ,J61347-1,J61347-2-13,IP67approved EN61347-1,EN61347-2-13independent ;DesignrefertoUL60950-1, TUVEN60950-1 54V 32.4~54V 0.76A 41.04W 350mVp-p 4.0% 0.5% 0.5% 42V 25.2~42V 0.96A 40.32W 250mVp-p 4.0% 0.5% 0.5% 88.5% 89% 15~17V 17.5~21V 23~27V 28~35V 34~40V 41~49V 54~63V 0.6A /115VAC0.3A /230VAC 46~54V 59~66V FileName:LPF-40D-SPEC 2011-07-28 40WSingleOutputSwitchingPowerSupply Universal AC input / Full range Built-in active PFC function High efficiency up to 89% Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection dimming function (1~10Vdc or PWM signal or resistance) Suitable for LED lighting and moving sign applications Compliance to worldwide safety regulations for lighting 3 years warranty (up to 305VAC) Suitable for dry / damp / wet locations Fully isolated plastic case Fully encapsulated with IP67 level (Note.6) Class power unit, no FG Built-in 3 in 1 Features : L P F - 4 0 D series ISOLATIONRESISTANCE CONSTANTCURRENTREGION Note.4 SAFETY STANDARDS Note.6 WITHSTANDVOLTAGE I/P-O/P:3.75KVAC I/P-O/P:100MOhms/500VDC/25 /70%RH EMCIMMUNITY Complianceto EN55015,EN61000-3-2ClassC( 60%load);EN61000-3-3 CompliancetoEN61000-4-2,3,4,5,6,8,11;EN61547,EN55024,lightindustrylevel(surge2KV),criteria A EMCEMISSION IP67 F M M 110 SELV ( for 48V,54V only) ( except for 48V,54V ) |
Similar Part No. - LPF-40D-42 |
|
Similar Description - LPF-40D-42 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |