Electronic Components Datasheet Search |
|
TEL185E Datasheet(PDF) 2 Page - Protek Devices |
|
TEL185E Datasheet(HTML) 2 Page - Protek Devices |
2 / 5 page Only One Name Means ProTek’Tion™ www.protekdevices.com 05050.R4 12/10 Page 2 TEL185B - TEL185E TyPICAL DEvICE CHARACTERIsTICs MAXIMuM RATINGs @ 25°C unless Otherwise specified PARAMETER syMBOL vALuE uNITs Peak Operating Line Voltage V OP ±185 Volts Operating Line Current I O 200 mA Transient Voltage - 20 kV/Wire Transient Current - 8/20µs waveform - 10 kA/Wire Transient Current - 8/20µs waveform - 40 kA/Protector Operating Temperature T A -55 to 100 °C Storage Temperature T STG -55 to 100 °C Response Time - < 1 ns ELECTRICAL CHARACTERIsTICs PER LINE @ 25°C unless Otherwise specified PART NuMBER MAXIMuM CLAMPING vOLTAGE (8/20µs) @ ±500A v C vOLTs MAXIMuM LINE THROuGHPuT REsIsTANCE R OHMs MAXIMuM LEAKAGE CuRRENT @ ±185v OP I D µA MAXIMuM CAPACITANCE @ 0v, 1MHz C pF TEL185B/E 330 12 5 800 INsTALLATION INsTRuCTIONs There are five (5) terminals on both the line and equipment side of the TEL185E - four telcom line terminals and one ground terminal. The ground terminal, as shown on the label, is connected internally. A single ground connection is sufficient. However, it is recommended that both ground connections be used for a lower imped- ance path to earth. This connection can be made through the green AC power ground wire or a known earth ground. The ground wire should be #14 stranded wire. Incoming telcom lines are cut or disconnected from the equipment to insert the TEL185E product. The line side of the terminals are to be connected to outside telephone or telecommunication lines that carry the transient threats into the equipment to be protected. The equipment side of the terminals are to be connected to the equipment to be protected. The location of the product should be such that these wires are as short as possible. A #18 or 20 gauge wire can be used for these connections. The TEL185B requires an edge connector interface for installation. A standard 15 position edge connector can be used. When mounting or wiring the connectors onto a printed circuit board, be sure that the correct terminals are soldered. The line side of the board connections are finger contacts 2 thru 5. The boards are conformal coated for limited protection against moisture. ProTek’s telcom line protector is designed with a short circuit failure mode to give maximum protection. A fuse, PTC, fusible link, or circuit breaker is recommended for each signal line on the input (line) side of the protector for those applications that require an open circuit failure mode. Caution: A low DC resistance ground may not be indicative of a good lightning ground. Lightning contains a broad spectrum of frequencies - up to 1 MHz. A low impedance path to ground at the transient frequencies is necessary. A ground strap is recommended or a #6 AWG stranded wire. For wire lengths over 1.5 meters, there may be some excessive line to earth potential under severe thunderstorm conditions. For these applications, an additional protector may be necessary at the equipment interface. |
Similar Part No. - TEL185E |
|
Similar Description - TEL185E |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |