Electronic Components Datasheet Search |
|
RPO3-1233SA Datasheet(PDF) 2 Page - Recom International Power |
|
RPO3-1233SA Datasheet(HTML) 2 Page - Recom International Power |
2 / 4 page ![]() www.recom-international.com 167 April-2005 Input Voltage Range 12V nominal input 9-18VDC 24V nominal input 18-36VDC 48V nominal input 36-75VDC Input Filter Pi Type Input Surge Voltage (100 ms max.) 12V Input 36VDC 24V Input 50VDC 48V Input 100VDC Input Reflected Ripple (nominal Vin and full load) 20mAp-p Start Up Time (nominal Vin and constant resistor load) 350ms typ. Output Power 3W max. Output Voltage Accuracy (full Load and nominal Vin) ±2% Minimum Load (see Note 1) 10% of FL Line Regulation (LL-HL at full load) ±0.2% Load Regulation (25% to 100% FL) Single ±0.2% Dual ±1% Cross Regulation (asymmetrical load 25%/100% FL) ±5% Ripple and Noise (20MHz bandwith) 50mVp-p Temperature Coefficient ±0.02%/°C, max. Transient Response (25% load step change) 200µS Over Load Protection (% of full load at nominal Vin) 180% typ Short Circuit Protection Continuous, automatic recovery Efficiency see „Selection Guide“ table continued on next page Specifications (typical at nominal input and 25°C unless otherwise noted) POWERLINE DC/DC-Converter RP03-S_DA Series 125 75 50 25 0 100 Ambient Temperature Range (°C) -25 -10 0 50 60 70 80 90 100 Natural Convection 125 75 50 25 0 100 Ambient Temperature Range (°C) -40-25-10 0 50 60 70 80 90 100 85 Natural Convection RP03-4805SA RP03-4805SA/M1 Derating-Graph (Ambient Temperature) Derating graphes are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at info@recom-development.at |