5 / 11 page CJ1W-CLK 5 Mountable Racks Note: 1. A CP1W-EXT01 CJ Unit Adaptor is required. 2. One NSJW-CLK21-V1 can be mounted to the NSJ Controller. 3. If an Expansion Rack is used, the NSJW-CLK21-V1 cannot be mounted to the NSJ Controller. Communications Specifications Note: 1. With wired models, the maximum number of nodes is 32 if Repeater Units are not used. A Repeater Unit is required when building a network with more than 32 nodes. If a Repeater Unit is used, be sure to use only the following Controller Link Units or Boards and set the Wired Network 62 Node Enable Bit in the DM Parameter Area software switches at all nodes. CS1W-CLK23/CLK21-V1 CJ1W-CLK23/CLK21-V1 3G8F7-CLK23-E/CLK21-EV1 2. CX-Net in CX-Programmer version 3.1 or earlier can be used only in a system with a maximum of 32 nodes (node address 1 to 32). If a system is to be used with a maximum of 62 nodes (node addresses 1 to 62), use CX-Net in CX-Programmer version 3.2 or higher or the CX-Integrator. 3. CJ-series PLCs do not have a Link Area, but LR000 to LR199 are automatically converted CIO 1000 to CIO 1199. Model CJ1 System CP1H System NSJ System CPU Rack Expansion Backplane CP1H PLC NSJ Controller Expansion Backplane CJ1W-CLK23 Unit version 2.0 8 Units (per CPU Unit) 2 Units (See note 1.) Not supported (See note 2.) 8 Units (See note 3.) CJ1W-CLK21-V1 Unit version 1.2 Items Specifications Model CJ1W-CLK23 3G8F7-CLK23-E CJ1W-CLK21-V1 3G8F7-CLK21-EV1 Type Wired (shielded twisted-pair cable) Communications method N:N token-bus method Code Manchester code Modulation Baseband code Synchronization Flag synchronization (conforms to HDLC frames) Transmission path format Multidrop method (bus type) Transmission speed The following are the maximum transmission distances depending on the transmission speed. 2 Mbits/s: 500 m 1 Mbits/s: 800 m 500 kbits/s: 1 km Maximum transmission distance Maximum distance between nodes Not specified. (Maximum transmission distance must be satisfied for the entire system.) Medium Specified shielded twist-pair cable Two signal wires, one shield Node connection method PLC: Connection to terminal block Computer: Connection using special (supplied) connector Maximum number of nodes 32 or 62 nodes (See note 1 and 2.) Applicable Programming Devices CX-Integrator in CX-One, CX-Net in CX-Programmer (See note 2.), and Programming Console Communications functions Data links and message service Number of data link words Send words per node: 4,000 words max. (CJ1W-CLK @3), 1,000 words max. (All other Units) Number of send/receive words per node: 12,000 words max. (Pre-Ver. 1.2) 20,000 words max. (unit Ver. 1.2 or later) Total number of send words per network: 62,000 words max. Data link areas PLC: Bit areas (CIO Area, Work Area, Link Area (See note 3.)), Data Memory (DM), Extended DM Area (EM) Computer: FinsGateway event memory Message length 2,012 bytes max. (including the header) RAS functions • Polling node backup function • Self-diagnosis function (hardware checking at startup) • Echoback test and broadcast test (using the FINS command) • Watchdog timer • Error log function Error control Manchester code check CRC check (CCITT X16+X12+X5+1) |
Similar Part No. - CJ1W-CLK21-V1 |
|
Similar Description - CJ1W-CLK21-V1 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |