LOK4001-2RLD Datasheet(PDF) 2 Page - Power-One

Part No. LOK4001-2RLD
Description  15, 30 and 50 Watt AC-DC Converters
Download  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  POWER-ONE [Power-One]
Direct Link  http://www.power-one.com
Logo POWER-ONE - Power-One

LOK4001-2RLD Datasheet(HTML) 2 Page - Power-One

  LOK4001-2RLD Datasheet HTML 1Page - Power-One LOK4001-2RLD Datasheet HTML 2Page - Power-One LOK4001-2RLD Datasheet HTML 3Page - Power-One LOK4001-2RLD Datasheet HTML 4Page - Power-One  
Zoom Inzoom in Zoom Outzoom out
 2 / 4 page
background image
243
www.power-one.com
Edition 5/07.2001
DIN Rail Mountable
LOS, LOR, LOK 4000 Series
Protection
Input fuse
not user accessible
1.6 A, slow blow
Input transient protection
voltage depending resistor (VDR)
Output
no-load, overload and short circuit proof
Control
Status indication
LED output O.K.
Output voltage adjustment
R input - recitfier version
90...110%
Uo nom
Output undervoltage monitoring D battery charger
typ. 80%
Uoset
Safety
Approvals
EN 60950, UL 1950, CSA22.2 No. 950, UL 508 listed
in progress
Electric strength test voltage
input/protective earth
1.5 kV AC
input/output
3 kV AC
output/protective earth
1 kV AC
Pollution degree
2
Degree of protection
IP 20
EMC
Electrostatic discharge
IEC/EN 61000-4-2, level 2 (8 kV)
criterion B
Electromagnetic field
IEC/EN 61000-4-3, level 2 (3 V/m)
criterion B
Electr. fast transients/bursts
IEC/EN 61000-4-4, level 3 (2 kV)
criterion B
Surge
IEC/EN 61000-4-5, level 3, line to prot. earth (2 kV)
criterion B
IEC/EN 61000-4-5, level 2, line to line (1 kV)
criterion B
Conducted disturbances
IEC/EN 61000-4-6, level 2 (3 V)
criterion A
Electromagnetic emissions
CISPR 22/EN 55022, conducted
class B
Environmental
Operating ambient temperature
Ui nom, Io nom, convection cooled
–10...50
°C
Operating case temperature
TC Ui nom, Io nom
–10...80
°C
Storage temperature
non operational
–40...85
°C
Damp heat
IEC/EN 60068-2-3, 93 %, 40
°C
21 days
Vibration, sinusoidal
IEC/EN 60068-2-6, 10...60/60...2000 Hz
0.15 mm/2 gn
Shock
IEC/EN 60068-2-27
11 ms/15 gn
Bump
IEC/EN 60068-2-29
11 ms/10 gn
MTBF
MIL-HDBK-217F, 6B, 40
°
1'600'000 h
Options
Built-in second fuse in the neutral
F
No fuse fitted
(operation from DC voltage)
F1
System connectors with screw terminals
K


Html Pages

1  2  3  4 


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn