Part # D6F-10A5
Description  MEMS Airflow Sensor
Download  8 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
Manufacturer  OMRON [Omron Electronics LLC]
Direct Link  http://www.omron.com/index3.html
Logo OMRON - Omron Electronics LLC

D6F-10A5 Datasheet(HTML) 3 Page - Omron Electronics LLC

  D6F-10A5 Datasheet HTML 1Page - Omron Electronics LLC D6F-10A5 Datasheet HTML 2Page - Omron Electronics LLC D6F-10A5 Datasheet HTML 3Page - Omron Electronics LLC D6F-10A5 Datasheet HTML 4Page - Omron Electronics LLC D6F-10A5 Datasheet HTML 5Page - Omron Electronics LLC D6F-10A5 Datasheet HTML 6Page - Omron Electronics LLC D6F-10A5 Datasheet HTML 7Page - Omron Electronics LLC D6F-10A5 Datasheet HTML 8Page - Omron Electronics LLC  
Zoom Inzoom in Zoom Outzoom out
 3 / 8 page
background image
MEMS Airflow Sensor
D6F-10A, -20A, -50A
3
Installation: D6F-10A5-000, D6F-20A5-000, D6F-50A5-000
Recommendation for right-angle connection
Tighten screw with 0.59Nm or less torque. Use M3 pan head screw.
Please seal to INLET and OUTLET with the ‘O’ ring etc. Please
install the product as shown below.
Recommended ‘O’ ring for sealing inlet and outlet orifice
Material: NBR70 (recommended)
Example part number: JASO part number: CO 0003
Alternative manufacturers with similar DO and W dimensions may be
used
■ Precautions
1. Avoid use in excessively dirty, wet environments
2. Do not use in the presence of flammable gases (e.g. hydrogen,
methane, ethane) and liquefied petroleum gas. In addition, do not
use with corrosive gases (e.g. chlorine, sulphur, acids, alkalis,
etc.).
3. Install in the direction of the arrow indicated.
4. For best results (optimum accuracy), mount horizontally.
5. Use four suitable M3 screws for mounting. Do not exceed a fixing
torque of 0.59 Nm.
6. Do not modify D6F- in any way.
7. Do not place any object in or close to the inlet and outlet orifices.
8. Do not use the sensor in any of the following environments:
• a location that receives radiant heat from the sun or apparatus
• a place where intense light may radiate down
• places where corrosive gas, especially sulphur and ammonia
gases are present
• where fast changing temperatures occur
• locations prone to freezing, high humidity, condensation
• places where large magnitudes of vibration or shock could occur
9. Noise countermeasures: VERY IMPORTANT: Take suitable pre-
cautions to minimize the effects and potential for induced electri-
cal noise. Install away from apparatus that generates strong high
frequencies, surges and spikes. Take particular care to install
away from AC power transformers, live mains power lines and
high power magnetic circuits. Attach a surge suppressor and a
noise filter to the peripheral equipment.
10.Ensure good grounding is achieved by grounding the GND termi-
nal to the peripheral equipment’s main ground frame connection
and its associated regulated power supply.
11.Do not make a direct solder connection to the integral terminals. It
is recommended you use the optional cable ‘D6F-CABLE1’ for
attachment and to ensure correct connection.
12.D6F- is a precision component. Keep in original packaging and
remove only when ready for installation. Damage may occur if
subjected to excessive force (e.g. dropped or kicked). Any item
suspected to be damaged should be discarded.
13.Immediately following installation, a qualified person should per-
form checks to ensure safe, satisfactory operation.


Similar Part No. - D6F-10A5

ManufacturerPart #DatasheetDescription
logo
Omron Electronics LLC
D6F-10A5-000 OMRON-D6F-10A5-000 Datasheet
568Kb / 6P
   MEMS Airflow Sensor
More results

Similar Description - D6F-10A5

ManufacturerPart #DatasheetDescription
logo
Omron Electronics LLC
D6F-10A OMRON-D6F-10A_10 Datasheet
568Kb / 6P
   MEMS Airflow Sensor
logo
List of Unclassifed Man...
AWM5104VN ETC2-AWM5104VN Datasheet
131Kb / 1P
   MASS AIRFLOW SENSOR
logo
Honeywell Accelerometer...
AWM1100V HONEYWELL-ACC-AWM1100V Datasheet
58Kb / 1P
   MASS AIRFLOW SENSOR
logo
Honeywell Solid State E...
AWM5104VA HONEYWELL-AWM5104VA Datasheet
130Kb / 1P
   MASS AIRFLOW SENSOR
logo
Honeywell Accelerometer...
AWM1200V HONEYWELL-ACC-AWM1200V Datasheet
57Kb / 1P
   MASS AIRFLOW SENSOR
AWM1300V HONEYWELL-ACC-AWM1300V Datasheet
59Kb / 1P
   MASS AIRFLOW SENSOR
logo
Analog Devices
TMP12 AD-TMP12_15 Datasheet
710Kb / 12P
   Airflow and Temperature Sensor
TMP12 AD-TMP12 Datasheet
446Kb / 14P
   Airflow and Temperature Sensor
REV. 0
logo
Omron Electronics LLC
D6F-P0010A OMRON-D6F-P0010A Datasheet
405Kb / 5P
   MEMS Flow Sensor
logo
ALPS ELECTRIC CO.,LTD.
HSPPAR ALPS-HSPPAR Datasheet
370Kb / 1P
   MEMS Pressure Sensor
More results


Html Pages

1 2 3 4 5 6 7 8


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com