Electronic Components Datasheet Search |
|
DS1305E+ Datasheet(PDF) 7 Page - Maxim Integrated Products |
|
DS1305E+ Datasheet(HTML) 7 Page - Maxim Integrated Products |
7 / 22 page ![]() DS1305 7 of 22 hour, and minute alarm registers is set to a logic 1. When bit 7 of the day, hour, minute, and seconds alarm registers is set to a logic 1, alarm occurs every second. During each clock update, the RTC compares the Alarm 0 and Alarm 1 registers with the corresponding clock registers. When a match occurs, the corresponding alarm flag bit in the status register is set to a 1. If the corresponding alarm interrupt enable bit is enabled, an interrupt output is activated. Table 2. TIME-OF-DAY ALARM MASK BITS ALARM REGISTER MASK BITS (BIT 7) SECONDS MINUTES HOURS DAYS FUNCTION 1 1 1 1 Alarm once per second 0 1 1 1 Alarm when seconds match 0 0 1 1 Alarm when minutes and seconds match 0 0 0 1 Alarm hours, minutes, and seconds match 0 0 0 0 Alarm day, hours, minutes and seconds match SPECIAL PURPOSE REGISTERS The DS1305 has three additional registers (control register, status register, and trickle charger register) that control the RTC, interrupts, and trickle charger. CONTROL REGISTER (READ 0Fh, WRITE 8Fh) BIT7 BIT6 BIT5 BIT4 BIT3 BIT2 BIT1 BIT0 EOSC WP 0 0 0 INTCN AIE1 AIEO EOSC (Enable Oscillator) – This bit when set to logic 0 starts the oscillator. When this bit is set to a logic 1, the oscillator is stopped and the DS1305 is placed into a low-power standby mode with a current drain of less than 100nA when power is supplied by VBAT or VCC2. On initial application of power, this bit will be set to a logic 1. WP (Write Protect) – Before any write operation to the clock or RAM, this bit must be logic 0. When high, the write protect bit prevents a write operation to any register, including bits 0, 1, 2, and 7 of the control register. Upon initial power-up, the state of the WP bit is undefined. Therefore, the WP bit should be cleared before attempting to write to the device. INTCN (Interrupt Control) – This bit controls the relationship between the two time-of-day alarms and the interrupt output pins. When the INTCN bit is set to a logic 1, a match between the timekeeping registers and the Alarm 0 registers activates the INT0 pin (provided that the alarm is enabled) and a match between the timekeeping registers and the Alarm 1 registers activate the INT1 pin (provided that the alarm is enabled). When the INTCN bit is set to a logic 0, a match between the timekeeping registers and either Alarm 0 or Alarm 1 activate the INT0 pin (provided that the alarms are enabled). INT1 has no function when INTCN is set to a logic 0. AIE0 (Alarm Interrupt Enable 0) – When set to a logic 1, this bit permits the interrupt 0 request flag (IRQF0) bit in the status register to assert INT0 . When the AIE0 bit is set to logic 0, the IRQF0 bit does not initiate the INT0 signal. |
Similar Part No. - DS1305E+ |
|
Similar Description - DS1305E+ |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |