2 / 4 page P2824 ETALDOC 438/10 Page 2 of 4 February 2006 SPECIFICATIONS Distortion Exceed requirements of EN 50065-1 for conducted emissions Conditions: Fundamental 132.45kHz into artificial mains network of EN 50065-1 at 116dBµV and AC magnetizing current of 3mA rms at 50Hz. Circuit as Figure 1. Voltage Isolation 4kVrms at 50Hz Operating range Ambient Storage Relative Humidity -25 to +85ºC -40 to +125ºC to 95% Typical lumped parameters as Fig. 2, referred to pins 1-3. Parameter Conditions Typical Units Series resistance RS (DCR+ AC resistance) 125kHz, 1V 1.3 Ω Leakage inductance ΔL 125kHz, 1V 46 µH Shunt inductance LP 125kHz, 1V 1200 µH Shunt loss RP 125kHz, 1V 50 k Ω Test Circuit Fig 1 1F µ 33nF MAINS Equivalent Circuit IDEAL 1:1 Fig 2 |
Similar Part No. - P2824 |
|
Similar Description - P2824 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |