Electronic Components Datasheet Search |
|
D1U4-W-1200-12-HC1C Datasheet(PDF) 2 Page - Murata Power Solutions Inc. |
|
D1U4-W-1200-12-HC1C Datasheet(HTML) 2 Page - Murata Power Solutions Inc. |
2 / 5 page Technical enquiries email: toronto@murata-ps.com, tel: +1 (866) 740 1232 www.murata-ps.com D1U4-W-1200-12-Hx Series AC/DC Front End Power Supply D1U4-1200-12-Hx.A03 Page 2 of 5 OUTPUT CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Remote Sense 120 mV Efficiency 220Vac 90.6 % Output Rise Monotonicity Overshoot less than 10% for all outputs, no voltage negative between 10% to 95% during ramp up Start-up Time AC ramp up 1.5 s PS_On activated 150 ms Transient Response 12V Ramp 1A/μs, 50% load step ±600 mV 3.3Vsb Ramp 1A/μs, 50% load step ±165 5Vsb Ramp 1A/μs, 50% load step ±250 Current sharing accuracy (up to 6 in parallel) At 100% load ±10 % Hot Swap Transients All outputs within regulation Hold-up Time Max. load, nominal Vin 20 ms GENERAL CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Storage Temperature Range Non-condensing -40 70 °C Operating Temperature Range 050 Operating Humidity Non-condensing 10 90 % Storage Humidity 590 Shock 30G non operating Sinusoidal Vibration 0.5G, 5 – 500 Hz operating MTBF Calculated per Bellcore at Ta=30°C 200 Khrs Demonstrated 200 Khrs Acoustic ISO 7779-1999 60 dB LpAm Safety Approvals c-CSA-us (CSA 60950-1-03/UL 60950-1, First Edition) TUV approval (Bauart) EN 60950-1:2001 Input Fuse Power Supply has internal 20A/250V fast blow fuse on the AC line input Material Flammability UL 94V-0 Switching Frequency 90KHz for Boost PFC Converter 165KHz for Main Output Converter 200KHz for Standby Output Converter Weight 2.1kg PROTECTION CHARACTERISTICS Output Voltage Parameter Conditions Min. Typ. Max. Units Over-temperature Auto-restart 55 65 °C 12V Over Voltage Latching 13 14 V Over Current Latching 107 122 A 3.3Vsb Over Voltage Latching 3.57 4.02 V Over Current Latching 6.5 8 A 5Vsb Over Voltage Latching 5.6 6 V Over Current Latching 5 7 A ISOLATION CHARACTERISTICS Parameter Conditions Min. Typ. Max. Units Insulation Safety Rating / Test Voltage Input to Output - Reinforced 3000 Vrms Input to Chassis - Basic 1500 Vrms Isolation Output to Chassis Output to Output Material Flammability UL 94V-0 Grounding Main Output Return and Standby Output Return are connected internally. 100kΩ resistor parallel with 100nF capacitor is connected between Return and power supply chassis. Main Output Return should be connected to the System Chassis. |
Similar Part No. - D1U4-W-1200-12-HC1C |
|
Similar Description - D1U4-W-1200-12-HC1C |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |