Electronic Components Datasheet Search
  English  ▼

Delete All
ON OFF
ALLDATASHEET.COM

X  

Preview PDF Download HTML

AEL15US03 Datasheet(PDF) 3 Page - XP Power Limited

Part No. AEL15US03
Description  AC-DC Power Supplies
Download  8 Pages
Scroll/Zoom Zoom In 100% Zoom Out
Maker  XPPOWER [XP Power Limited]
Homepage  http://www.xppower.com
Logo 

AEL15US03 Datasheet(HTML) 3 Page - XP Power Limited

   
Zoom Inzoom in Zoom Outzoom out
 3 / 8 page
background image
Specification
20-60 Watts
CEC 2008 & EISA 2007 Compliant
Approved as LPS
China Compulsory Certfication (CCC) Qualified
Up to 88% Efficiency
+70 °C Operating Temperature
Compact Dimensions
20 W Optional Class II Insulation
AEL Series
Input
Input Voltage
• 90-264 VAC
Input Frequency
• 47-63 Hz
Input Current
• 0.4 A max AEL20
1.0 A max AEL40
1.6 A max AEL60
Inrush Current
• 15 A/30 A for 115 VAC/230 VAC, cold start
Earth Leakage Current
• 0.75 mA at 240 VAC (except C2 version)
Power Factor
• Meets EN61000-3-2
Input Protection
• Fitted with internal fuse,
1 A AEL20, 2 A AEL40/60
Standby Power
• Typically 0.3 W, max 0.5 W
Consumption
Output
Output Voltage
• See tables
Minimum Load
• No minimum load required
Hold Up Time
• 12 ms min AEL20, 16 ms AEL40/60,
at full load 110 VAC
Start Up Delay
• 0.5 s AEL20/40, 2.0 s AEL60,
at full load 100 VAC
Transient Response
• 2% deviation, recovery to within 1% of
nominal in 500 µs for 50% load change
Line Regulation
• See tables
Load Regulation
• See tables
Ripple & Noise
• 1% pk-pk max, 20 MHz BW
Overvoltage Protection • 112-132%
Overload Protection
• 110-150%
Short Circuit Protection • Trip & restart (Hiccup mode), auto recovery
Temperature
• ±0.04%/°C
Coefficient
xppower.com
General
Efficiency
• 85% typical AEL20/40,
88% typical AEL60
Isolation
• 3000 VAC Input to Output
1500 VAC Input to Ground (not C2 version)
500 VDC Output to Ground (not C2 version)
Switching Frequency
• 63 kHz typical
MTBF
• 300 kHrs AEL20, 200 kHrs AEL40,
130 kHrs AEL60 to MIL-STD-217F
Environmental
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +40 °C to 50% power at +70 °C
Storage Temperature
• -40 °C to +85 °C
Cooling
• Convection cooled
Operating Humidity
• 5-95% RH, non-condensing
Operating Altitude
• 3000 m
Shock
• 10 g, 10 ms on 3 axes
Vibration
• 5-100 Hz 2.31 m/s2, 20 mins 3 axes
EMC & Safety
Emissions
• EN55022 FCC Part-15C Level B
conducted & radiated
Harmonic Current
• EN61000-3-2 Class A
Voltage Flicker
• EN61000-3-3
ESD Immunity
• EN61000-4-2 Level 3 Perf criteria A
Radiated Immunity
• EN61000-4-3 3 V/m Perf criteria A
EFT/Burst
• EN61000-4-4 Level 2 Perf criteria A
Surge
• EN61000-4-5 Level 3 Perf criteria A
Conducted Immunity
• EN61000-4-6 Level 2 Perf criteria A
Magnetic Field
• EN61000-4-8 1 A/m Perf criteria A
Dips & Interruptions
• EN61000-4-11, 70% UT for 500 ms,
40% UT for 100 ms, <5% UT for 5000 ms
Perf criteria A, B, B
Safety Approvals
• EN60950-1:2001, UL/cUL60950-1,
Approved as Limited Power Source,
CE Mark, China Compulsory Certification
(CCC) qualified.


Html Pages

1  2  3  4  5  6  7  8 


Datasheet Download




Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn