Back Button LTC2919HMS-2.5-PBF Datasheet HTML 2Page - Linear Technology LTC2919HMS-2.5-PBF Datasheet HTML 3Page - Linear Technology LTC2919HMS-2.5-PBF Datasheet HTML 4Page - Linear Technology LTC2919HMS-2.5-PBF Datasheet HTML 5Page - Linear Technology LTC2919HMS-2.5-PBF Datasheet HTML 6Page - Linear Technology LTC2919HMS-2.5-PBF Datasheet HTML 7Page - Linear Technology LTC2919HMS-2.5-PBF Datasheet HTML 8Page - Linear Technology LTC2919HMS-2.5-PBF Datasheet HTML 9Page - Linear Technology LTC2919HMS-2.5-PBF Datasheet HTML 10Page - Linear Technology Next Button
Zoom Inzoom in Zoom Outzoom out
 6 / 16 page
background image
LTC2919
6
2919f
PI FU CTIO S (MSOP/DFN Package)
SEL (Pin 1): Input Polarity Select Three-State Input. Con-
nect to VCC, GND or leave unconnected in open state to
select one of three possible input polarity combinations
(refer to Table 1).
VCC (Pin 2): Power Supply. Bypass this pin to ground with
a 0.1μF (or greater) capacitor. Operates as a direct supply
input for voltages up to 6V. Operates as a shunt regulator
for supply voltages greater than 6V and should have a
resistor between this pin and the supply to limit VCC input
current to no greater than 10mA. When used without a
current-limiting resistor, pin voltage must not exceed 6V.
UVLO options allow VCC to be used as an accurate third
fixed -10% UV supply monitor.
OUT1 (Pin 3): Open-Drain Logic Output 1. Asserts low
when positive polarity ADJ1 voltage is below threshold or
negative polarity ADJ1 voltage is above threshold. Requires
an external pull-up resistor and may be pulled above VCC.
OUT2 (Pin 4): Open-Drain Logic Output 2. Asserts low
when positive polarity ADJ2 voltage is below threshold
or negative polarity ADJ2 voltage is above threshold.
Requires an external pull-up resistor and may be pulled
above VCC.
RST (Pin 5): Open-Drain Inverted Reset Logic Output.
Asserts low when any positive polarity input voltage is
below threshold or any negative polarity input voltage is
above threshold or VCC is below UVLO threshold. Held
low for a timeout period after all voltage inputs are valid.
Requires an external pull-up resistor and may be pulled
above VCC.
GND (Pin 6): Device Ground.
REF (Pin 7): Buffered Reference Output. 1V nominal
reference used for the offset of negative-monitoring ap-
plications. The buffered reference can source and sink
up to 1mA. The reference can drive a capacitive load of
up to 1000pF. Larger capacitance may degrade transient
performance. This pin does not require a bypass capacitor,
nor is one recommended. Leave open if unused.
TMR (Pin 8): Reset Timeout Control. Attach an external
capacitor (CTMR) to GND to set a reset timeout period
of 9ms/nF. A low leakage ceramic capacitor is recom-
mended for timer accuracy. Capacitors larger than 1μF
(9 second timeout) are not recommended. See Applica-
tions Information for further details. Leaving this pin open
generates a minimum timeout of approximately 400μs. A
2.2nF capacitor will generate a 20ms timeout. Tying this
pin to ground will enable the internal 200ms timeout. Ty-
ing this pin to VCC will disable the reset timer and put the
part in comparator mode. Signals from the comparator
outputs will then go directly to RST.
ADJ2 (Pin 9): Adjustable Voltage Input 2. Input to volt-
age monitor comparator 2 (0.5V nominal threshold). The
polarity of the input is selected by the state of the SEL
pin (refer to Table 1). Tie to GND if unused (with SEL =
GND or Open).
OUT1, OUT2, RST VOL vs Output
Sink Current
ISEL vs Temperature
ISEL vs Temperature
OUTPUT SINK CURRENT (mA)
0
0.6
0.8
1.0
20
2919 G16
0.4
0.2
0
5
10
15
25
30
TA = 150°C
TA = 125°C
TA = 25°C
VCC = 3V
NO PULL-UP R
TA = –40°C
TEMPERATURE (°C)
–50 –25
–22
–18
–12
–10
0
50
75
2919 G17
–20
–14
–16
25
100
150
125
SEL = GND
TEMPERATURE (°C)
–50 –25
10
14
22
20
0
50
75
2919 G18
12
18
16
25
100
150
125
SEL = VCC
TYPICAL PERFOR A CE CHARACTERISTICS TA = 25°C unless otherwise noted.


Similar Part No. - LTC2919HMS-2.5-PBF

ManufacturerPart #DatasheetDescription
logo
Linear Technology
LTC2919 LINER-LTC2919_15 Datasheet
197Kb / 16P
   Precision Triple/Dual Input UV, OV and Negative Voltage Monitor
More results

Similar Description - LTC2919HMS-2.5-PBF

ManufacturerPart #DatasheetDescription
logo
Linear Technology
LTC2919 LINER-LTC2919_15 Datasheet
197Kb / 16P
   Precision Triple/Dual Input UV, OV and Negative Voltage Monitor
LTC2909 LINER-LTC2909_15 Datasheet
196Kb / 16P
   Precision Triple/Dual Input UV, OV and Negative Voltage Monitor
LTC2909 LINER-LTC2909 Datasheet
235Kb / 16P
   Precision Triple/Dual Input UV, OV and Negative Voltage Monitor
LTC2913 LINER-LTC2913 Datasheet
281Kb / 12P
   Dual UV/OV Voltage Monitor
LTC2913 LINER-LTC2913_15 Datasheet
181Kb / 12P
   Dual UV/OV Voltage Monitor
logo
Analog Devices
ADCMP671 AD-ADCMP671 Datasheet
312Kb / 16P
   Low Power, Adjustable UV and OV Monitor
REV. 0
logo
Linear Technology
LTC2912CTS8-2TRPBF LINER-LTC2912CTS8-2TRPBF Datasheet
178Kb / 12P
   Single UV/OV Voltage Monitor
LTC2912 LINER-LTC2912_15 Datasheet
228Kb / 14P
   Single UV/OV Voltage Monitor
LTC2912 LINER-LTC2912 Datasheet
173Kb / 12P
   Single UV/OV Voltage Monitor
LTC2914 LINER-LTC2914_15 Datasheet
259Kb / 18P
   Quad UV/OV Positive/Negative Voltage Monitor
More results


Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16


Datasheet Download

Go To PDF Page


Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com