CY2308
Document Number: 38-07146 Rev. *F
Page 6 of 14
Operating Conditions for Industrial Temperature Devices
Parameter
Description
Min
Max
Unit
VDD
Supply Voltage
3.0
3.6
V
TA
Operating Temperature (Ambient Temperature)
–40
85
°C
CL
Load Capacitance, below 100 MHz
–
30
pF
Load Capacitance, from 100 MHz to 133 MHz
–
15
pF
CIN
Input Capacitance[6]
–7
pF
tPU
Power up time for all VDDs to reach minimum specified voltage (power
ramps must be monotonic)
0.05
50
ms
Electrical Characteristics for Industrial Temperature Devices
Parameter
Description
Test Conditions
Min
Max
Unit
VIL
Input LOW Voltage
–
0.8
V
VIH
Input HIGH Voltage
2.0
–
V
IIL
Input LOW Current
VIN = 0V
–
50.0
μA
IIH
Input HIGH Current
VIN = VDD
–100.0
μA
VOL
Output LOW Voltage[7, 8]
IOL = 8 mA (–1, –2, –3, –4)
IOL = 12 mA (–1H, –5H)
–0.4
V
VOH
Output HIGH Voltage[7, 8]
IOH = –8 mA (–1, –2, –3, –4)
IOH = –12 mA (–1H, –5H)
2.4
–
V
IDD (PD mode)
Power Down Supply Current
REF = 0 MHz
–
25.0
μA
IDD
Supply Current
Unloaded outputs, 100 MHz, Select
inputs at VDD or GND
–
45.0
mA
–
70(–1H,–5H)
mA
Unloaded outputs, 66 MHz REF (–1,
–2, –3, –4)
–
35.0
mA
Unloaded outputs, 66 MHz REF (–1,
–2, –3, –4)
–
20.0
mA
Switching Characteristics for Industrial Temperature Devices
Parameter[8]
Name
Test Conditions
Min
Typ
Max
Unit
t1
Output Frequency
30 pF load, All devices
10
–
100
MHz
t1
Output Frequency
20 pF load, –1H, –5H devices[9]
10
–
133.3
MHz
t1
Output Frequency
15 pF load, –1, –2, –3, –4 devices
10
–
133.3
MHz
tPD
Duty Cycle[7, 8] = t2 ÷ t1
(–1, –2, –3, –4, –1H, –5H)
Measured at 1.4V, FOUT = 66.66 MHz
30 pF load
40.0
50.0
60.0
%
t3
Rise Time[7, 8]
(–1, –2, –3, –4)
Measured between 0.8V and 2.0V,
30 pF load
–
–
2.50
ns
t3
Rise Time[7, 8]
(–1, –2, –3, –4)
Measured between 0.8V and 2.0V,
15 pF load
–
–
1.50
ns
t3
Rise Time[7, 8]
(–1H, –5H)
Measured between 0.8V and 2.0V,
30 pF load
–
–
1.50
ns
t4
Fall Time[7, 8]
(–1, –2, –3, –4)
Measured between 0.8V and 2.0V,
30 pF load
–
–
2.50
ns
t4
Fall Time[7, 8]
(–1, –2, –3, –4)
Measured between 0.8V and 2.0V,
15 pF load
–
–
1.50
ns
t4
Fall Time[7, 8]
(–1H, –5H)
Measured between 0.8V and 2.0V,
30 pF load
–
–
1.25
ns
[+] Feedback