Electronic Components Datasheet Search |
|
AXIOM75 Datasheet(PDF) 2 Page - Advanced XTAL Products |
|
AXIOM75 Datasheet(HTML) 2 Page - Advanced XTAL Products |
2 / 2 page ![]() AXIOM75 www.axtal.com Wasemweg 5 page 2(2) fon: +49 (6261) 939834 D-74821 Mosbach fax: +49 (6261) 939836 Germany E-mail: info@axtal.com GmbH & Co. KG Enclosure drawing Pin connections Pin # Symbol Function 1 RF OUT RF Output 2 GND Ground, case 3 VC Control Voltage (EFC) 4 N.C. No Connection 5 VS Supply Voltage Environmental conditions Test IEC 60068 Part ... IEC 60679-1 clause ... Test conditions Visual inspection, dimensions 4.3 Enclosure styles as in IEC 60679-3 or 61837, if applicable Sealing tests (if applicable) 2-17 4.6.2 Gross leak: Test Qc, Fine leak: Test Qk Solderability Resistance to soldering heat 2-20 2-58 4.6.3 Test Ta (235 ± 5)°C Method 1 Test Tb Method 1A, 5s Shock* 2-27 4.6.8 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Bump* 2-29 4.6.6 Test Eb, 4000 bumps per Axes, 40g, 6 ms Free fall* 2-32 4.6.9 Test Ed procedure 1, 2 drops from 1m height Vibration, sinusoidal* 2-6 4.6.7 Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Rapid change of temperature 2-14 4.6.5 Test Na, 10 cycles at extremes of operating temperature range Dry heat 2-2 4.6.14 Test Ba, 16 h at upper temperature indicated by climatic category Damp heat, cyclic* 2-30 4.6.15 Test Db variant 1 severity b), 55°C/95% r.H., 6 cycles Cold 2-1 4.6.16 Test Aa, 2 h at lower temperature indicated by climatic category Climatic sequence* 1-7 4.6.17 Sequence of 4.6.14, 4.6.15 (1 st cycle), 4.6.16, 4.6.15 (5 cycles) Damp heat, steady state* 2-3 4.6.18 Test Ca, 56 days Endurance tests - ageing - extended aging 4.7.1 4.7.2 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C |