Electronic Components Datasheet Search |
|
M29DW640F90N6E Datasheet(PDF) 21 Page - Numonyx B.V |
|
M29DW640F90N6E Datasheet(HTML) 21 Page - Numonyx B.V |
21 / 74 page M29DW640F Command interface 21/74 4 Command interface All Bus Write operations to the memory are interpreted by the Command Interface. Commands consist of one or more sequential Bus Write operations. Failure to observe a valid sequence of Bus Write operations will result in the memory returning to Read mode. The long command sequences are imposed to maximize data security. The address used for the commands changes depending on whether the memory is in 16- bit or 8-bit mode. See either Table 6, or Table 7, depending on the configuration that is being used, for a summary of the commands. 4.1 Standard commands 4.1.1 Read/Reset command The Read/Reset command returns the memory to its Read mode. It also resets the errors in the Status Register. Either one or three Bus Write operations can be used to issue the Read/Reset command. The Read/Reset command can be issued, between Bus Write cycles before the start of a program or erase operation, to return the device to read mode. If the Read/Reset command is issued during the timeout of a Block erase operation then the memory will take up to 10µs to abort. During the abort period no valid data can be read from the memory. The Read/Reset command will not abort an Erase operation when issued while in Erase Suspend. 4.1.2 Auto Select command The Auto Select command is used to read the Manufacturer Code and Device Code, the Block Protection Status and the Extended Block Indicator. It can be addressed to either Bank. Three consecutive Bus Write operations are required to issue the Auto Select command. The final Write cycle must be addressed to one of the Banks. Once the Auto Select command is issued Bus Read operations to the Bank where the command was issued output the Auto Select data. Bus Read operations to the other Bank will output the contents of the memory array. The memory remains in Auto Select mode until a Read/Reset or CFI Query command is issued. This command must be issued addressing the same Bank, as was given when entering Auto Select Mode. In Auto Select mode the Manufacturer Code can be read using a read operation, A6 and A3 to A0 each held at VIL, and A21-A19 set to the Bank Address. The other address bits may be set to either VIL or VIH. The Device Codes can be read using a read operation, A6 held at VIL, A3 to A0 each held at the levels given in Table 4 and Table 5, and A21-A19 set to the Bank Address. The other address bits may be set to either VIL or VIH. The Block Protection Status of each block can be read using a read operation, A6 A3 A2 A0 each held at VIL, A1 held at VIH, and A21-A19 set to the Bank Address, and A18-A12 specifying the address of the block inside the Bank. The other address bits may be set to either VIL or VIH. If the addressed block is protected then 01h is output on Data Inputs/Outputs DQ0-DQ7, otherwise 00h is output. |
Similar Part No. - M29DW640F90N6E |
|
Similar Description - M29DW640F90N6E |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |