11 / 17 page 1.0 Functional Description (Continued) 1.9 COMMUNICATING with the LM82 10129709 There are 13 data registers in the LM82, selected by the Command Register. At power-up the Command Register is set to “00”, the location for the Read Local Temperature Register. The Command Register latches the last location it was set to. Reading the Status Register resets T_CRIT_A and INT, so long as a temperature comparison does not signal a fault (see Sections 1.2 and 1.3). All other registers are predefined as read only or write only. Read and write registers with the same function contain mirrored data. A Write to the LM82 will always include the address byte and the command byte. A write to any register requires one data byte. Reading the LM82 can take place either of two ways: 1. If the location latched in the Command Register is cor- rect (most of the time it is expected that the Command Register will point to one of the Read Temperature Reg- isters because that will be the data most frequently read from the LM82), then the read can simply consist of an address byte, followed by retrieving the data byte. 2. If the Command Register needs to be set, then an address byte, command byte, repeat start, and another address byte will accomplish a read. The data byte has the most significant bit first. At the end of a read, the LM82 can accept either Acknowledge or No Acknowledge from the Master (No Acknowledge is typically used as a signal for the slave that the Master has read its last byte). 1.10 SERIAL INTERFACE ERROR RECOVERY The LM82 SMBus lines will be reset to the SMBus idle state if the SMBData or SMBCLK lines are held low for 40 ms or more (t TIMEOUT). The LM82 may or may not reset the state of the serial interface logic if either of the SMBData or SMBCLK lines are held low between 25 ms and 40 ms. TIMEOUT allows a clean recovery in cases where the master may be reset while the LM82 is transmitting a low bit thus preventing possible bus lock up. Whenever the LM82 sees the start condition its serial inter- face will reset to the beginning of the communication, thus the LM82 will expect to see an address byte next. This simplifies recovery when the master is reset while the LM82 is transmitting a high. www.national.com 11 |
Similar Part No. - LM82 |
|
Similar Description - LM82 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |