DC Operating Conditions
Parameter
Description
Condition
Min
Max
Unit
VDDP
Supply Voltage for PLL
2.5V ± 5%
2.375
2.625
V
VDDC
Supply Voltage for Core
2.5V ± 5%
2.375
2.625
V
VDD
Supply Voltage for Clock Buffers
2.5V ± 5%
2.375
2.625
V
VIHCLK
Input High Voltage, REFCLK/REFCLKB
0.6
0.95
V
VILCLK
Input Low Voltage, REFCLK/REFCLKB
–0.15
+0.15
V
VIXCLK
[6]
Crossing Point Voltage, REFCLK/REFCLKB
200
550
mV
ΔV
IXCLK
[6]
Difference in Crossing Point Voltage, REFCLK/REFCLKB
–
150
mV
VIH
Input Signal High Voltage at ID0, ID1, EN, and /BYPASS
1.4
2.625
V
VIL
Input Signal Low Voltage at ID0, ID1, EN, and /BYPASS
–0.15
0.8
V
VIH,SM
Input Signal High Voltage at SCL and SDA[7]
1.4
3.465
V
VIL,SM
Input Signal Low Voltage at SCL and SDA
–0.15
0.8
V
VTH
[8]
Input Threshold Voltage for single-ended REFCLK
0.35
0.5VDD
V
VIH,SE
Input Signal High Voltage for single-ended REFCLK
VTH + 0.3
2.625
V
VIL,SE
Input Signal Low Voltage for single-ended REFCLK
–0.15
VTH – 0.3
V
TA
Ambient Operating Temperature
0
70
°C
Notes
6. Not 100% tested except VIXCLK and ΔVIXCLK. Parameters guaranteed by design and characterizations, not 100% tested in production.
7. This range of SCL and SDA input high voltage enables the CY24272 for use with 3.3V, 2.5V, or 1.8V SMBus voltages.
8. Single-ended operation guaranteed only when 0.8 < (VIH,SE – VTH)/(VTH – VIL,SE) < 1.2.