3 / 9 page
3
HM6268 Series
HM6268 Series
Recommended DC Operating Conditions (Ta = 0 to + 70°C)
Parameter
Symbol
Min
Typ
Max
Unit
VCC
4.5
5.0
5.5
V
VSS
0
00V
Input high (logic 1) voltage
VIH
2.2
—
6.0
V
Input low (logic 0) voltage
VIL
–0.5 *1
—
0.8
V
Note:
1. –3.0 V for pulse width
≤ 10 ns.
DC Characteristics (VCC = 5 V ± 10%, VSS = 0 V, Ta = 0 to +70°C)
Parameter
Symbol
Min
Typ *1
Max
Unit
Test condition
Input leakage current
| ILI |
——
2.0
µA
VCC = 5.5 V,
Vin = VSS to VCC
Output leakage current
| ILO |
—
—
2.0
µA
CS = V
IH,
VI/O = VSS to VCC
Operating power supply current
ICC
—50 *3
90
mA
CS = V
IL, II/O = 0 mA,
min. cycle
Standby power supply current
ISB
—15
25
mA
CS = V
IH, min. cycle
—
0.02
2.0
mA
—1 *2
50 *2
µA
Output low voltage
VOL
—
—
0.4
V
IOL = 8 mA
Output high voltage
VOH
2.4
—
—
V
IOH = –4.0 mA
Notes:
1. Typical limits are at VCC = 5.0 V, Ta = +25°C and specified loading
2. This characteristic is guaranteed only for L-version.
3. 40 mA typical for 45 ns version.
Capacitance (Ta = 25°C, f = 1.0 MHz) *1
Parameter
Symbol Test conditions
Min
Max
Unit
Input capacitance
Cin
Vin = 0 V
—
6
pF
Input/output capacitance
CI/O
VI/O = 0 V
—
9
pF
Note:
1. These parameters are sampled and not 100% tested.
CS
≥ V
CC – 0.2 V,
0 V
≤ V
IN ≤ 0.2 V or
VCC – 0.2 V ≤ VIN
Standby power supply current (1) ISB1
Supply voltage