Electronic Components Datasheet Search |
|
P12 Datasheet(PDF) 2 Page - DB Lectro Inc |
|
P12 Datasheet(HTML) 2 Page - DB Lectro Inc |
2 / 2 page 3 4 5 7 8 6 10 9 Single Side stable 1 Coil latching 2 Coil latching 10 9 7 8 6 4 3 5 10 9 8 7 6 3 4 5 2 1 2 1 2 1 Index mark (De-energized Position) (Reset Position) Index mark Index mark (Reset Position) S R S: Set R: Reset (Bottom View) S R Wiring diagram (Bottom view) Mounting (Bottom view) NOTES 1).Dimensions are in millimeters. 2).Inch equivalents are given for general information only. 0.1 0.04 2.54 Tolerance: 0.1/0.004 10- 1 P Terminals strength 5N IEC68-2-21 Test Ua1 Solderability 235 2 3 0.5s IEC68-2-20 Test Ta method 1 Temperature Range -40~70 (-40~158 F) Mass 1.5g Characteristics Electrostatic capacitance Between open Contacts Approx.0.4pF Item 3.41 of IEC255-7 Between coil & Contacts Approx.0.9pF Item 3.41 of IEC255-7 Between Contact Poles Approx.0.2pF Item 3.41 of IEC255-7 Insulation Resistance 1000M min (at 500VDC) Item 7 of IEC255-5 Dielectric Strength Between open Contacts 1000VAC 1min Between coil & Contacts 1000VAC 1min Item 6 of IEC255-5 Item 6 of IEC255-5 Item 6 of IEC255-5 Between Contact Poles 1000VAC 1min Surge Withstand Voltage Between open Contacts 1500V FCC68 Between coil & Contacts 1500V FCC68 Between Contact Poles 2500V FCC68 Shock resistance 2 Functional:500m/s 11ms; 2 Survival:1000 m/s 6ms IEC68-2-27 Test Ea Vibration resistance 10~55Hz Double amplitude Functional 3mm Survival:5mm IEC68-2-6 Test Fc Qualification inspection: Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24. Safety approvals Safety approval UL&CUR Load 1A,2A/30VDC, 0.5A/125VAC mm/inch Dimensions Dimensions Index Mark 14max. 0.55max. 2.54 0.1 0.5 0.02 0.25 0.01 7.62 0.3 14.0 9.0 5.0 P P L 12 W 1 2 3 4 P-004 4.5 11.25 144.6 3.38 0.45 0.14 P-005 5 12.5 178 3.75 0.5 0.14 P-006 6 15.0 257 4.50 0.6 0.14 P-009 9 22.5 579 6.75 0.9 0.14 P-012 12 30.0 1028 9.00 1.2 0.14 P-024 24 48.0 2880 18.0 2.4 0.20 Approx.2 PL-003 3 8.7 90 2.25 -2.25 0.10 PL-005 5 14.5 250 3.75 -3.75 0.10 PL-006 6 17.4 360 4.50 -4.50 0.10 PL-009 9 26.1 810 6.75 -6.75 0.10 PL-012 12 34.8 1440 9.00 -9.00 0.10 PL-024 24 57.6 3840 18.0 -18.0 0.15 PK-003 3 6 45 45 2.25 2.25 0.20 PK-005 5 10 125 125 3.75 3.75 0.20 PK-006 6 12 180 180 4.50 4.50 0.20 PK-009 9 18 405 405 6.75 6.75 0.20 PK-012 12 24 720 720 9.00 9.00 0.20 PK-024 24 36 1920 1920 18.0 18.0 0.30 R E158859 C US Patent No 02217796.5 P-003 3 7.5 64.3 2.25 0.3 0.14 Approx.1 PL-004 4.5 13.0 202.5 3.38 -3.38 0.10 PK-004 4.5 9 101 3.38 3.38 0.20 101 R5604271 U T V 1A/30VDC, 0.5A/125VAC Ningbo Huaguan Relay Corporation LTD. 1 Part number P 3 Coil rated voltage(V) DC:3,4.5,5,6,9,12,24 2 Operating function NIL: Single Side Stable 4 Contact material NIL: AgPd W: AgNi L:1 Coil Latching; K:2 Coil Latching Features Ordering Information DIL Pitch Terminals .High Sensitivity :0.14W or 0.10W Nominal Power Conforms to FCC Part 68 1.5kV Surge and Dielectric 1000VAC Monostable or bistable relays Single and double Coil magnet latching Type available Application for Telecommunication Equipment,Office Equipment,Security Alarm Systems, Measuring instruments, Medical Monitoring Equipment,Audio Visual Equipment, Flight Simulator,Sensor Control Contact Data Contact Arrangement 2C DPDT(B-M) Bifurcated Crossbar Contact Material AgPd(Stationary Contact: Gold clad ) AgNi(Gold clad Contact Rating (resistive) 1A,2A/30VDC; 0.5A/125VAC Max. Switching Power 60W 62.5VA Min. Switching load 0.01mA/10mV Reference Value Max. Switching Voltage 220VDC 250VAC M ax. Swit ching Curr ent:2A Contact Resistance or Voltage drop Operation life 5 5 1A/30VDC 2 10 Ag Ni 1 10 5 0.5A/125VAC 1 10 Item 3.30 of IEC255-7 8 Mechanical 10 Item 3.31 of IEC255-7 50m Item 3.12 of IEC255-7 Electrical Coil Parameter Release /Reset Time ms Coil voltage VDC Coil resistance 10% Pick up voltage VDC(max) (75%of rated voltage ) Release voltage VDC(min) (10% of rated voltage) Coil power W Operate Time ms Rated Max. Dash numbers CAUTION: Relays previously tested or used above 10mA resistive at 6V maximum DC or peak AC open circuit are not recommended for subsequent use in low level applications. 1 Coil Latching Reset(Max) Reset 2 Coil Latching Set Coil Reset Coil Reset(Max) Reset Approx.2 Approx.1 Approx.2 Approx.1 CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 2.Pickup and release(reset) voltage are for test purposes only and are not to be used as design criteria. 3.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously. Coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to be in the magnetically neutral position . NHG RELAYS |
Similar Part No. - P12 |
|
Similar Description - P12 |
|
|
Link URL |
Privacy Policy |
ALLDATASHEET.COM |
Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Datasheet Upload | Contact us | Privacy Policy | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
Family Site : ic2ic.com |
icmetro.com |