2 / 11 page
CY62148B MoBL™
Document #: 38-05039 Rev. *C
Page 2 of 11
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Storage Temperature ................................. –65°C to +150°C
Ambient Temperature with
Power Applied............................................. –55°C to +125°C
Supply Voltage on VCC to Relative GND........ –0.5V to +7.0V
DC Voltage Applied to Outputs
in High Z State[1] .....................................–0.5V to VCC +0.5V
DC Input Voltage[1]..................................–0.5V to VCC +0.5V
Current into Outputs (LOW)......................................... 20 mA
Static Discharge Voltage...............................................2001V
(per MIL-STD-883, Method 3015)
Latch-Up Current ..................................................... >200 mA
Product Portfolio
Product
VCC Range
Speed
Temp.
Power Dissipation
Operating, Icc
Standby (ISB2)
f = fmax
Typ.[3]
Max.
Min.
Typ.
Max.
Typ.[3]
Max.
CY62148BLL
4.5 V
5.0V
5.5V
70 ns
Com’l
12.5 mA
20 mA
4
µA
20
µA
Ind’l
Operating Range
Range
Ambient
Temperature[2]
VCC
Commercial
0°C to +70°C
4.5V–5.5V
Industrial
–40°C to +85°C
Electrical Characteristics Over the Operating Range
Parameter
Description
Test Conditions
CY62148B-70
Unit
Min.
Typ.[3]
Max.
VOH
Output HIGH Voltage
VCC = Min., IOH = – 1 mA
2.4
V
VOL
Output LOW Voltage
VCC = Min., IOL = 2.1 mA
0.4
V
VIH
Input HIGH Voltage
2.2
VCC+0.3
V
VIL
Input LOW Voltage
–0.3
0.8
V
IIX
Input Leakage Current
GND
≤ V
I ≤ VCC
–1
+1
µA
IOZ
Output Leakage
Current
GND
≤ V
I ≤ VCC, Output Disabled
–1
+1
µA
ICC
VCC Operating
Supply Current
f = fMAX = 1/tRC
Com/Ind’l
IOUT =0 mA
VCC = Max.,
12.5
20
mA
f = 1 MHz
2.5
mA
ISB1
Automatic CE
Power-Down Current
—TTL Inputs
Max. VCC,
CE
≥ V
IH
VIN ≥ VIH or
VIN ≤ VIL, f = fMAX
Com/Ind’l
1.5
mA
ISB2
Automatic CE
Power-Down Current
—CMOS Inputs
Max. VCC,
CE
≥ V
CC – 0.3V,
VIN ≥ VCC – 0.3V,
or VIN ≤ 0.3V, f =0
Com/Ind’l
4
20
µA
Notes:
1. VIL (min.) = –2.0V for pulse durations of less than 20 ns.
2. TA is the “Instant On” case temperature.
3. Typical values are measured at VCC = 5V, TA = 25°C, and are included for reference only and are not tested or guaranteed.
[+] Feedback
[+] Feedback