Note: The PWMx Current Duty Cycle register is implemented as two separate registers: a read-only
and a write-only.
When a value is written to this register in manual mode there will be a delay
before the programmed value can be read back by software. The hardware updates the read-
only PWMx Current Duty Cycle register on the beginning of a PWM cycle. If Ramp Rate
Control is disabled, the delay to read back the programmed value will be from 0 seconds to
1/(PWM frequency) seconds. Typically, the delay will be 1/(2*PWM frequency) seconds.
7.1.3.2
Auto Fan Control Operating Mode
The EMC2300 implements automatic fan control. In Auto Fan Mode, this device automatically adjusts
the PWM duty cycle of the PWM outputs, according to the flow chart on the following page (see
Figure 7.1 Automatic Fan Control Flow Diagram on page 32).
PWM outputs are assigned to a thermal zone based on the PWMx Configuration registers (see Section
6.9, "Thermal Zones," on page 28). It is possible to have more than one PWM output assigned to a
thermal zone. For example, PWM outputs 2 and 3, connected to two chassis fans, may both be
controlled by thermal zone 2. At any time, if the temperature of a zone exceeds its absolute limit, all
PWM outputs go to 100% duty cycle to provide maximum cooling to the system (except those fans
that are disabled or in manual mode).
It is possible to have a single fan controlled by multiple zones, turning on when either zone requires
cooling based on its individual settings.
A VCC POR resets all values to their initial or default states.
If the start bit is one, the Auto Fan Control block will evaluate the temperature in the zones configured
for each Fan in a round robin method. The Auto Fan Control block completely evaluates the zones for
all three fans in a maximum of 0.25sec.


Html Pages

1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23  24  25  26  27  28  29  30  31  32  33  34  35  36  37  38  39  40  41  42  43  44  45  46  47  48  49  50  51  52  53  54  55  56  57  58  59  60  61  62  63  64  65  66  67  68  69  70  71  72  73  74  75  76  77  78  79  80  81 


Datasheet Download




Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn