SLLS741 – JUNE 2006
ORDERING INFORMATION
TA
PACKAGE(1)
ORDERABLE PART NUMBER
TOP-SIDE MARKING
Tube of 70
MAX3318ECDB
SSOP – DB
MP318EC
Reel of 2000
MAX3318ECDBR
–0
°C to 70°C
Tube of 70
MAX3318ECPW
TSSOP – PW
MP318EC
Reel of 2000
MAX3318ECPWR
Tube of 70
MAX3318EIDB
SSOP – DB
MP318EI
Reel of 2000
MAX3318EIDBR
–40
°C to 85°C
Tube of 70
MAX3318EIPW
TSSOP – PW
MP318EI
Reel of 2000
MAX3318EIPWR
(1)
Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at
www.ti.com/sc/package.
DETAILED DESCRIPTION
Flexible control options for power management are featured when the serial port and driver inputs are inactive.
The auto-power-down plus feature functions when FORCEON is low and FORCEOFF is high. During this mode
of operation, if the device does not sense valid signal transitions on all receiver and driver inputs for
approximately 30 s, the built-in charge pump and drivers are powered down, reducing the supply current to
1
µA. By disconnecting the serial port or placing the peripheral drivers off, auto-power-down plus can be
disabled when FORCEON and FORCEOFF are high. With auto-power-down plus enabled, the device activates
automatically when a valid signal is applied to any receiver or driver input. INVALID is high (valid data) if any
receiver input voltage is greater than 2.7 V or less than –2.7 V, or has been between –0.3 V and 0.3 V for less
than 30
µs (typical number). INVALID is low (invalid data) if all receiver input voltage are between –0.3 V and
0.3 V for more than 30
µs (typical number).
2
Submit Documentation Feedback


Html Pages

1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18 


Datasheet Download




Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn