AD7329
Rev. 0 | Page 10 of 40
Pin No.
Mnemonic
Descriptions
17
MUXOUT
Negative Multiplexer Output. This pin allows access to the on-chip track-and-hold. The voltage applied to this
pin is still a high voltage signal when the AD7329 is in differential mode. When the AD7329 is in single-ended
mode, this signal is AGND, and MUXOUT− can be connected directly to the ADCIN− pin. When the AD7329 is in
pseudo differential mode, a small dc voltage appears at this pin, and this pin should be tied to the ADCIN− pin.
18
ADCIN
Negative ADC Input. This pin allows access to the track-and-hold. When the AD7329 is in single-ended mode,
this pin can be tied to MUXOUT−, which is connected to AGND. When the AD7329 is in pseudo differential
mode, this pin should be connected to MUXOUT−. When the AD7329 is in true differential mode, the voltage
applied to this pin is a high voltage signal (±10 V, ±5 V, ±2.5 V, or 0 V to +10 V).
9 to 16
VIN0 to VIN7
Analog Input 0 Through Analog Input 7. The analog inputs are multiplexed into the on-chip track-and-hold.
The analog input channel for conversion is selected by programming the channel address bits, ADD2
through ADD0, in the control register. The inputs can be configured as eight single-ended inputs, four true
differential input pairs, four pseudo differential inputs, or seven pseudo differential inputs. The configuration
of the analog inputs is selected by programming the mode bits, Mode 1 and Mode 0, in the control register.
The input range on each input channel is controlled by programming the range registers. Input ranges of
±10 V, ±5 V, ±2.5 V, or 0 V to +10 V can be selected on each analog input channel (see the Range Registers
section). On power up, VIN0 is automatically selected and the voltage on this pin appears on MUXOUT+.


Html Pages

1  2  3  4  5  6  7  8  9  10  11  12  13  14  15  16  17  18  19  20  21  22  23  24  25  26  27  28  29  30  31  32  33  34  35  36  37  38  39  40 


Datasheet Download




Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn