N1500 Datasheet(PDF) 1 Page - Artesyn Technologies

Part No. N1500
Description  Single, and dual output 1500 and 2000 Watt AC/DC high wattage power supplies with PFC
Download  4 Pages
Scroll/Zoom Zoom In 100% Zoom Out
Maker  ARTESYN [Artesyn Technologies]
Homepage  
Logo 

N1500 Datasheet(HTML) 1 Page - Artesyn Technologies

   
Zoom Inzoom in Zoom Outzoom out
 1 / 4 page
background image
OUTPUT SPECIFICATIONS (2)
Voltage adjustability
Accessible at front panel
±10%
Remote sense
Open/reverse sense lead protection
Compensates for voltage drop of up to
0.5V to the load
Regulation, line or load
All outputs, NL-FL
±0.2%;
at nominal line or all
10mV min.
line variations at FL
Cross regulation
0.2% max. or 10mV between outputs
Overshoot/undershoot
None at turn-on/off
Transient response
Main output
≤2.0% max. dev.,
25% step load
≤200µs recovery
change at 1A/µs
to 1.0%
Temperature coefficient
±0.02%/°C
Ripple and noise
0Hz to 20MHz
50mV pk-pk or 1.0%
Overvoltage protection
Reset by cycling AC
115 to 130%
of nominal
Overload protection
105-115% full load
Short circuit protection
All outputs
Auto recovery
Thermal protection
Auto shutdown, AC reset
Current sharing
±5.0%
50% to 100% load
Current monitor (V1)
5VDC at full load
±0.5V
INPUT SPECIFICATIONS
Input voltage range
180 to 264VAC
Input frequency range
47Hz to 63Hz
Input surge current
Meets IEEE std. 587.1980;
3KV ring wave
Input current
230VAC, 2000W
13A
Power factor
230VAC, 2kW load
0.98 min.
Power up time
Full load
1.0s max.
EMC CHARACTERISTICS
Radiated emissions
EN55022/11, FCC part 15
Level A
Conducted emissions
EN55022/11, FCC part 15
Level A
Harmonic distortion
EN61000-3-2
Conforms
Electrostatic discharge
EN61000-4-2
Level 3
RF field susceptibility
EN61000-4-3
Level 3
Electrical fast
EN61000-4-4
Level 3
transients/bursts
Surge susceptibility
EN61000-4-5
Level 3
GENERAL SPECIFICATIONS
Hold-up time
180VAC, 2kW load
15ms min.
Efficiency
230VAC, full load
73%
Isolation voltage
Input/output
3000VAC
Input/chassis
1500VAC
Output/output
500VAC
Switching frequency
100kHz
Approvals and
EN60950, UL1950,
standards
CSA C22.2 No. 950
Weight
6.9kg (15Ibs)
Size
5 x 8 x 11 inches
127 x 203.2 x 279.4 mm
MTBF
per MIL-HDBK-217E
100,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient
0°C to +50°C
Non-operating
-15°C to +85°C
Cooling
60CFM
Internal DC ball bearing fan
Relative humidity
Non-condensing
0% to 95% RH
Altitude
Operating
6,000 feet max.
Non-operating
55,000 feet max.
Vibration
5Hz to 500Hz
2.4G rms peak
N1500 and N2000 SERIES
Single, and dual output
[ 2 YEAR WARRANTY ]
• Active harmonic correction to EN61000-3-2
• 180VAC to 264VAC input voltage range
• Flexible output voltage configuration
• Two output power ratings
• Forced current sharing, all outputs
• DC OK (including LED)
• UL, CSA and TÜV safety approvals
• Industry standard 5 x 8 x 11 inch footprint
The N1500 and N2000 series are a range of system-orientated, single or dual output
power supplies with output powers of 1500W and 2000W. Harmonically corrected, they
operate from 180VAC to 264VAC. World wide safety approvals are standard. Fan
cooled and enclosed in the industry standard 5 x 8 x 11 inch form, the N1500 and N2000
series are an ideal choice when the economy and predictable performance of a
centralized system power supply are desired. By utilizing dual high current converters,
operating independently or together, a wide variety of output voltage and current
combinations can be factory configured. The N1500 and N2000 extend the range of the
N1000 family. Forced current share provides higher current to satisfy needs in large
systems, or to power expansion chassis. Dual output models at 5VDC/12VDC are
perfect to power mass storage systems. Other applications might use 5VDC/3.3VDC,
both operating at high currents. Single output versions, operating alone or in redundant
mode provide an economic power source for distributed systems. System interface
signals include AC and DC good, current monitor (V1). OVP, OCP, overtemperature
protection, remote enable, margin check inhibit as standard. By combining robust
performance and broad range, the N1500 and N2000 series sets the standard for
centralized system power supplies.
SPECIFICATION All specifications are typical at nominal input, full load at 25°C unless otherwise stated
PAGE 1


Html Pages

1  2  3  4 


Datasheet Download




Link URL




Privacy Policy
ALLDATASHEET.COM
Does ALLDATASHEET help your business so far?  [ DONATE ]  

About Alldatasheet   |   Advertisement   |   Datasheet Upload   |   Contact us   |   Privacy Policy   |   Alldatasheet API   |   Link Exchange   |   Manufacturer List
All Rights Reserved© Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn