Electronic Components Datasheet Search |
|
PL384XBP8 Datasheet(PDF) 4 Page - Cystech Electonics Corp. |
|
PL384XBP8 Datasheet(HTML) 4 Page - Cystech Electonics Corp. |
4 / 15 page ![]() CYStech Electronics Corp. Spec. No. : C510P8 Issued Date : 2003.04.24 Revised Date : Page No. : 4/15 PL384XBP8 CYStek Product Specification Electrical Characteristics (continued) Parameter Test Conditions Symbol Min. Typ. Max. Unit Undervoltage Lockout Section PL3842B/PL3844B 14.5 16 17.5 V Start Threshold PL3843B/PL3845B 7.8 8.4 9.0 V Min Operating Voltage After Turn-on PL3842B/PL3844B PL3843B/PL3845B 8.5 7.0 10 7.6 11.5 8.2 V PWM Section PL3842B/PL3843B 94 96 100 % Maximum Duty Cycle PL3844B/PL3845B 47 48 50 % Minimum Duty Cycle - - 0 % Total Standby Current VI=6.5V for PL3843B/45B Ist - 0.3 0.5 mA Start-up Current VI=14V for PL3842B/44B - 0.3 0.5 mA Operating Supply Current VPIN 2 = VPIN 3 = 0V II - 12 17 mA Zener Voltage II = 25 mA VIZ 30 36 - V Notes: 1. Max. package power dissipation limits must be respected; low duty cycle pulse techniques are used during test maintain Tj as close to Tamb as possible. 2.These parameters, although guaranteed, are not 100% tested in production. 3.Parameter measured at trip point of latch with VPIN 2= 0 . 4.Gain defined as: 5. Adjust VI above the start threshold before setting at 15V. A= ∆VPIN 1 ∆VPIN 3 , 0 ≤ VPIN 3 ≤ 0.8V |